Stanford Research SR430 – Multichannel Scaler/Averager

The Stanford Research SR430 Multichannel Scaler/Averager is a versatile instrument used for time-resolved photon counting, mass spectrometry, and other applications requiring high-speed data acquisition and signal averaging. It features multiple channels for simultaneous data collection, allowing for efficient and accurate measurements of time-varying signals. Its advanced triggering and timing capabilities enable precise control over data acquisition, while its built-in averaging functions improve signal-to-noise ratio.

Model
Stanford Research SR430
Calibration
Available on request
Price
$2,950
Status
In stock
RFQ ref
SR430
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Stanford Research SR430 Multichannel Scaler/Averager is a high-speed data acquisition instrument designed for photon counting, event timing, and signal analysis. It combines amplification, discrimination, bin clocking, and real-time averaging into a single unit, eliminating the need for external analysis systems. The SR430 handles count rates to 100 MHz with no interchannel dead time, making it ideal for time-resolved measurements in LIDAR, time-of-flight mass spectrometry, and fluorescence decay analysis.


Technical Specifications



  • Count Rate Capacity: 100 MHz maximum

  • Bin Width: 5 ns to 10 ms (selectable); external bin clock input supported for custom sizing

  • Bins per Record: 1,024 to 32,768 in 1k increments

  • Records per Scan: 1 to 65,536, or continuous free-run mode

  • Input Impedance: 50 Ω

  • Analog Input Range: ±300 mV

  • Input Sensitivity: 10 mV minimum pulse amplitude

  • Discriminator Range: ±300 mV, adjustable in 0.2 mV steps

  • Discriminator Accuracy: 2 mV + 1%

  • Pulse-Pair Resolution: 10 ns (typical)

  • Discriminator Output: NIM level (0 to –0.7 V, active low) with 20 ns insertion delay

  • Trigger Input Impedance: 10 kΩ

  • Trigger Threshold: –2.000 V to +2.000 V in 1 mV steps

  • Power Consumption: 60 W

  • Power Supply: 100, 120/220, 240 VAC, 50/60 Hz


Key Features



  • Selectable positive or negative slope for discriminator and trigger functions

  • Record-by-record averaging with add/subtract capability and polarity control

  • External inhibit input for selective record exclusion

  • External toggle input for dynamic polarity selection

  • Real-time on-screen data display and analysis

  • Hardcopy output to Epson-compatible dot-matrix and HP LaserJet printers, plus HP-GL plotters

  • Data transfer to hardcopy at 16,384 bins in 500 ms

  • 3.5" DOS-compatible floppy drive (720 kB) for program and data storage


Interfaces IEEE-488.2, RS-232, and Centronics printer connectivity enable remote instrument control and data retrieval.


Typical Applications Time-of-flight systems, single-photon detection experiments, temporal correlation measurements, and any application requiring synchronized event counting with high timing resolution.

Specifications

ParameterValue
Voltage / Current Range100/120/220/240 VAC, 50/60 Hz

Stanford Research SR430 — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Stanford Research SR430. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Stanford Research SR430 price

This Stanford Research SR430 is listed at $2,950. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Stanford Research SR430 calibration cost

NIST-traceable calibration for the Stanford Research SR430 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →