Agilent / Keysight U2000A 10 MHz – 18 GHz USB Power Sensor

Agilent / Keysight RF Power Sensors. Frequency Range: 10 MHz to 18 GHz, Dynamic Range: -60 dBm to +20 dBm (Low Power Path: -60 to -10 dBm, Resolution: 1.0.

Model
Agilent / Keysight U2000A
Calibration
Available on request
Price · starting from
$3,500
Status
In stock
RFQ ref
U2000A
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Agilent/Keysight U2000A is a USB power sensor that delivers precise RF and microwave power measurements from 10 MHz to 18 GHz. Connected directly to a PC via USB 2.0, it eliminates the need for a separate benchtop power meter and streamlines test system integration. The sensor spans a dynamic range of -60 dBm to +20 dBm with dual measurement paths optimized for low and high power levels, achieving measurement uncertainty of ≤1.9% at room temperature.


Technical Specifications



  • Frequency Range: 10 MHz to 18 GHz

  • Dynamic Range: -60 dBm to +20 dBm (Low Power Path: -60 to -10 dBm; High Power Path: -10 to +20 dBm)

  • Measurement Speed: Up to 250 readings/second

  • Measurement Uncertainty: ≤1.9% at room temperature (excluding power level dependent terms)

  • Display Resolution: 1.0, 0.1, 0.01, 0.001 dB in log mode; one to four digits in linear mode

  • Power Offset Range: -100 dB to +100 dB in 0.001 dB increments

  • Limit Configuration: -150.00 dBm to +230.000 dBm in 0.001 dBm increments

  • Connector Type: Type-N (male)

  • Dimensions: 163.75 mm (L) × 46 mm (W) × 35.9 mm (H)


Key Features



  • Dual-path architecture optimizes sensitivity and dynamic range across the full power spectrum

  • Internal and external triggering with burst envelope detection and graphical trace display for gate placement refinement

  • Internal zeroing capability; external zeroing recommended for power levels below -30 dBm

  • Selectable measurement units: Watts (W), dBm (absolute), or percentage of dB (relative)

  • High and low limit thresholds with 0.001 dBm resolution

  • SCPI-compatible for industry-standard system integration


Typical Applications



  • RF and microwave power validation in production test environments

  • Source power calibration with PNA network analyzers

  • Signal generator verification in test setups with MXG generators

  • Handheld spectrum analyzer integration (N9340A/B compatibility)


Compatibility & Integration



  • Controlled by BenchVue software (version 3.0+) and the BV0007B Power Meter/Sensor Control and Analysis app at no cost

  • Compatible with N1918A Power Analysis Manager software

  • Integrates with Keysight MXG signal generators, N9340A/B spectrum analyzers, and PNA network analyzers

  • USB 2.0 cable supplied in 1.5 m length; 3.0 m and 5.0 m options available

  • Optional BNC (male) to SMB (female) trigger cable for external triggering

Agilent / Keysight U2000A — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Agilent / Keysight U2000A. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Agilent / Keysight U2000A price

This Agilent / Keysight U2000A is listed at $3,500. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Agilent / Keysight U2000A calibration cost

NIST-traceable calibration for the Agilent / Keysight U2000A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →