Advantest U4342N – RF Field Analyzer
Advantest Spectrum Analyzers. Frequency Range: 9 kHz to 2.2 GHz, Power Range (dBm): -95 dBm (tracking generator output); −10 dBm (sensitivity reference), Voltage / Current Range: 100/230 V AC; +10 to +16 V DC.
- Model
- Advantest U4342N
- Calibration
- Available on request
- Price
- $850
- RFQ ref
- U4342N
This unit
The Advantest U4342N RF Field Analyzer is a portable instrument for precise RF signal analysis across telecommunications, RF design, and EMC testing applications. Operating from 9 kHz to 2.2 GHz with 75 Ω input impedance, it delivers 100 dB display dynamic range and sensitivity to ≤16 dBµV at 30 MHz. The integrated 20 dB pre-amplifier, tracking generator (100 kHz to 2.2 GHz), and specialized demodulation functions - including TDMA-TDD waveform observation and TV picture/sound demodulation - enable comprehensive field measurements.
A 6-inch color TFT LCD with ±15° tilt adjustment provides clear visibility in variable lighting. Dual PCMCIA memory card slots store settings and measured data with dust-proof protection. The unit operates on AC (100/230 V), DC (+10 to +16 V), or an internal battery pack delivering approximately 2 hours runtime with 1-hour recharge time.
Measuring 148 (H) × 291 (W) × 330 (D) mm and weighing 6.8 kg without battery, it meets demanding field portability requirements while maintaining performance across +0°C to +50°C operating temperatures.
Technical Specifications
- Frequency Range: 9 kHz to 2.2 GHz
- Input Impedance: 75 Ω
- Display Dynamic Range: 100 dB
- Sensitivity: ≤16 dBµV at 30 MHz (reference -10 dBm at 20–30°C)
- Pre-Amplifier Gain: 20 dB (integrated)
- Tracking Generator Output: 100 kHz to 2.2 GHz; harmonic distortion <−20 dBc; non-harmonic distortion <−30 dBc; VSWR ≤1.5 (100 kHz to 2 GHz), ≤2.0 (100 kHz to 2.2 GHz)
- Power Supply: 100/230 V AC; +10 to +16 V DC; battery pack (~2 hours operation, 1-hour recharge)
- Display: 6-inch color TFT LCD, ±15° tilt
- Dimensions: 148 (H) × 291 (W) × 330 (D) mm
- Weight: 6.8 kg (without battery); 9 kg (with battery)
- Operating Temperature: +0°C to +50°C, ≤85% RH (non-condensing)
- Storage Temperature: −20°C to +60°C, ≤85% RH (non-condensing)
Key Features
- TDMA-TDD waveform observation with single-slot burst analysis (625 µs) and ID-triggered sweep initiation; demodulated CI, CS-ID, and PS-ID display
- TV demodulation function for picture/sound analysis in broadcast IF and CATV uplink bands
- Frequency characteristic measurement via tracking generator; impedance matching and return loss evaluation via directional coupler
- Dual PCMCIA memory card slots (JEIDA Ver. 4.1/PCMCIA Rel. 2.0) with dust-proof shutters for panel and data storage
- Reduced dB measurement capability
Typical Applications
- Telecommunications signal verification
- RF impedance and return loss characterization
- EMC field testing and compliance verification
- Broadcast and CATV system analysis
Compatibility & Integration
- PCMCIA memory card storage (JEIDA Ver. 4.1/PCMCIA Rel. 2.0) for field data portability
- Multi-voltage DC input (+10 to +16 V) for varied power distribution systems
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 9 kHz to 2.2 GHz | Power Range (dBm): '-95 dBm (tracking generator output) |
| −10 dBm (sensitivity reference) | Voltage / Current Range | 100/230 V AC |
Advantest U4342N — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Advantest U4342N. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.
Advantest U4342N price
This Advantest U4342N is listed at $850. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Advantest U4342N calibration cost
NIST-traceable calibration for the Advantest U4342N is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →