NI USB-6008 12-Bit Multifunction DAQ USB Device

NI Data Acquisition Systems (DAQ). Model: USB-6008.

Model
NI USB-6008
Calibration
Available on request
Price
$539
Status
In stock
RFQ ref
USB-6008
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The NI USB-6008 is a low-cost, 12-bit multifunction DAQ device built for USB 2.0 Full-Speed connectivity and bus-powered operation. It delivers analog input across 8 single-ended or 4 differential channels at 10 kS/s aggregate sample rate, two 12-bit analog outputs up to 150 S/s, 12 individually configurable digital I/O channels, and a 32-bit event counter supporting edge counting to 5 MHz. The device suits data logging, mobile measurements, and educational applications with selectable differential input ranges from ±1 V to ±20 V and single-ended ±10 V operation.


Successive approximation conversion with 41.67 ns timing resolution (24 MHz timebase) and 100 ppm timing accuracy ensures reliable signal acquisition. System noise ranges from 0.5 mVrms at ±1 V to 5 mVrms at full scale, with absolute accuracy of 1.53 mV to 14.7 mV depending on range. A single 32-bit counter accepts falling-edge events on PFI 0, configurable as digital trigger or counter input.


The device provides +5 V auxiliary power up to 200 mA and a +2.5 V external reference. Lightweight, portable enclosure with screw terminal connectors (16–28 AWG) and overvoltage protection to ±35 V rounds out the design. NI-DAQmx driver software simplifies configuration and measurement execution across Windows and embedded platforms.


Technical Specifications

Analog Input

  • 8 single-ended or 4 differential channels

  • 12-bit resolution, ±1 V to ±20 V differential ranges, ±10 V single-ended

  • 10 kS/s aggregate sample rate, successive approximation converter

  • 144 kΩ input impedance, ±35 V overvoltage protection

  • System noise: 0.5–5 mVrms; absolute accuracy 1.53–14.7 mV @ 25 °C Analog Output

  • 2 channels, 12-bit resolution, 0–5 V range

  • 150 S/s maximum update rate, software-timed Digital I/O

  • 12 channels, individually configurable input/output

  • Port 0: channels 0–7; Port 1: channels 0–3 Event Counter

  • 1× 32-bit counter, falling-edge detection to 5 MHz

  • 100 ns minimum pulse width, PFI 0 configurable as trigger or counter input Power & Reference

  • +5 V @ 200 mA auxiliary output; +2.5 V external reference provided

  • USB bus-powered via USB 2.0 Full-Speed (12 Mb/s)


Key Features



  • Screw terminal connectors accommodate 16–28 AWG wire

  • Timing resolution 41.67 ns, 100 ppm accuracy

  • Compact, portable design suitable for field deployment

  • NI-DAQmx driver integration for rapid application development


Typical Applications



  • Basic data logging and mobile sensor measurements

  • Educational laboratory experiments and bench-top testing

  • Signal conditioning and low-speed transducer monitoring


Compatibility & Integration Supported by NI-DAQmx driver software; operates as USB 2.0 Full-Speed device on standard Windows and Linux platforms with Python, C, and LabVIEW compatibility.

Specifications

ParameterValue
Frequency Range5 MHz (event counter maximum input frequency) | Voltage / Current Range: '+2.5 V (external reference), +5 V @ 200 mA (auxiliary output), ±1 V to ±20 V (differential AI), ±10 V (single-ended AI), 0–5 V (AO)

NI USB-6008 — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the NI USB-6008. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

NI USB-6008 price

This NI USB-6008 is listed at $539. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

NI USB-6008 calibration cost

NIST-traceable calibration for the NI USB-6008 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →