NI USB-6210 16-Bit Multifunction DAQ
NI Data Acquisition Systems (DAQ). Voltage: ±10.4 V relative to AI GND, Current: +100 pA, Resolution: # Digital I/O.
- Model
- NI USB-6210
- Calibration
- Available on request
- Price
- $1,790
- Status
- In stock
- RFQ ref
- USB-6210
This unit
The NI USB-6210 is a bus-powered, 16-bit multifunction data acquisition module delivering analog input, analog output, and digital I/O capabilities over USB connectivity. Engineered for portability and field deployment, it serves engineers and scientists requiring flexible measurement and control in space-constrained or mobile environments.
Technical Specifications
-# Analog Input- 16 single-ended or 8 differential channels
- 16-bit ADC resolution
- 250 kS/s maximum sample rate (multichannel aggregate and single-channel)
- Programmable input ranges: ±0.2 V, ±1 V, ±5 V, ±10 V
- DC coupling
- Maximum working voltage: ±10.4 V relative to AI GND
- CMRR (DC to 60 Hz): 100 dB
- Input impedance (device on): >10 GΩ || 100 pF; (device off): 1,200 Ω
- Input bias current: +100 pA
- Crosstalk: -75 dB (adjacent channels), -90 dB (non-adjacent channels) at 100 kHz
- Small signal bandwidth (-3 dB): 450 kHz
- Settling time: 4 µs (±90 ppm), 5 µs (±30 ppm), 7 µs (±15 ppm)
- Overvoltage protection: ±30 V (device on, two pins), ±20 V (device off, two pins); ±20 mA max input current during overvoltage
- Absolute accuracy example (±10 V range): 2,690 µV; gain error 132 ppm, offset error 130 ppm, noise uncertainty 68.7 µV -# Analog Output
- 2 channels
- 16-bit resolution -# Digital I/O
- 4 digital input channels, 4 digital output channels
- TTL logic levels
- Input range: 0 V to 5.25 V
- Output range: 0 V to 3.8 V
- Current drive: 16 mA (single pin), 50 mA (all pins)
- Input current flow: sinking; output current flow: sourcing
- Protection: ±10 V -# Counters & Timing
- Two 32-bit counters (frequency measurement, event counting, pulse generation)
- Timing resolution: 50 ns
- Timing accuracy: 50 ppm of sample rate
Key Features
- Bus-powered operation eliminates external power supply requirements
- High input impedance (>10 GΩ) minimizes loading effects
- Excellent CMRR and crosstalk isolation for precision multi-channel measurements
- Wide programmable input ranges accommodate diverse sensor outputs
- Integrated counter functions support timing and synchronization tasks
Typical Applications
- Portable sensor data logging and real-time monitoring
- Control system prototyping and validation
- Laboratory measurement and test automation
- Field-based condition monitoring and diagnostics
Compatibility & Integration USB connectivity enables immediate deployment on Windows-based systems. NI driver support and LabVIEW integration streamline configuration and data handling.
Specifications
| Parameter | Value |
|---|---|
| Voltage / Current Range | ±0.2 V, ±1 V, ±10 V (AI) |
NI USB-6210 — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the NI USB-6210. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.
NI USB-6210 price
This NI USB-6210 is listed at $1,790. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
NI USB-6210 calibration cost
NIST-traceable calibration for the NI USB-6210 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →