Abaco Systems / VMIC VMIVME-3118-000 32-Channel 16-Bit A/D Converter Module

Abaco Systems / VMIC Data Acquisition Systems (DAQ). Voltage / Current Range: ±10 V, ±2.5 V, ±25 mV to ±10 V, ±5 V, 0 to +10 V, 0 to +5 V, Current: ≤50 nA, Voltage: (0.3 + 6/G + 0.6k) mV.

Model
Abaco Systems / VMIC VMIVME-3118-000
Calibration
Available on request
Price
$3,499
Status
In stock
RFQ ref
VMIVME-3118-000
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Abaco Systems/VMIC VMIVME-3118-000 is a VMEbus-compatible analog-to-digital converter module delivering 32 channels of 16-bit data acquisition. It captures analog signals at up to 52 kSPS with configurable input ranges, programmable gain stages, and optional filtering for demanding measurement applications across industrial, laboratory, and scientific environments.


Technical Specifications

Analog Input

  • 32 channels, differential or single-ended

  • 16-bit resolution

  • Full-scale ranges: ±2.5 V, ±5 V, ±10 V, 0 to +5 V, 0 to +10 V, ±25 mV to ±10 V (selectable)

  • Programmable gain: ×1, ×10, ×100

  • Input impedance: 5 MΩ || 50 pF

  • Input bias current: ≤50 nA

  • Input noise: 0.3 mV RMS (DC–100 Hz)

  • Overvoltage protection: ±40 V maximum

  • Input offset voltage: (0.3 + 6/G + 0.6k) mV, where G = gain and k = sample rate in KSPS A/D Conversion

  • Conversion rate: 52 kSPS maximum

  • Channel sample rate: 3.25 kSPS (all 16 channels in block)

  • Conversion cycle: 19 µs (acquisition, conversion, storage)

  • Integral nonlinearity: ±0.005% (best straight line)

  • Differential nonlinearity: ±0.0015% typical at MSB

  • Quantization error: ±1/2 LSB

  • Missing codes: 0.6% maximum at 16-bit

  • Data coding: Two's complement or offset binary (selectable) Gain & Accuracy

  • PGA nonlinearity (DC): ±0.005% FSR (G=1, 10), ±0.01% FSR (G=100)

  • Gain accuracy: ±0.008% FSR (G=1), ±0.06% FSR (G=10, 100)

  • System accuracy drift: ±20 PPM/°C (G=1), ±50 PPM/°C (G=10), ±90 PPM/°C (G=100)

  • PGA offset drift: ±(3 + 15/G) µV/°C

  • Total noise: ≤4,500 µV (G=1, FS=±10 V) Filtering

  • Optional low-pass filters: 10 Hz, 50 Hz, 100 Hz, 500 Hz, 1.6 kHz (-3 dB cutoff) Crosstalk

  • Adjacent channels: -80 dB (DC), -60 dB (10 Hz), -70 dB (50 Hz)

  • Alternate channels: -110 dB (DC, 50 Hz), -100 dB (10 Hz)


Key Features



  • Wide input range selectivity via jumper and software control

  • Selectable low-pass filtering for noise rejection

  • High input impedance minimizes loading effects

  • Excellent INL/DNL performance supports precision instrumentation


Typical Applications



  • Multi-channel data acquisition on VMEbus backplanes

  • Process monitoring and industrial control

  • Laboratory instrumentation and signal measurement

  • Scientific research requiring simultaneous sampling


Compatibility & Integration Module operates within standard VMEbus architectures. Hardware gain selection via jumper or software programming accommodates signal conditioning without external amplification.

Specifications

ParameterValue
Voltage / Current Range±10 V, ±2.5 V, ±25 mV to ±10 V, ±5 V, 0 to +10 V, 0 to +5 V

Abaco Systems / VMIC VMIVME-3118-000 — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Abaco Systems / VMIC VMIVME-3118-000. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Abaco Systems / VMIC VMIVME-3118-000 price

This Abaco Systems / VMIC VMIVME-3118-000 is listed at $3,499. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Abaco Systems / VMIC VMIVME-3118-000 calibration cost

NIST-traceable calibration for the Abaco Systems / VMIC VMIVME-3118-000 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →