Abaco Systems / VMIC VMIVME-4120-000 16-Channel D/A Current or Voltage Output Board
The VMIVME-4120-000 is a 16-channel D/A current or voltage output board from Abaco Systems / VMIC. Designed for VMEbus systems, it provides high-resolution analog outputs suitable for industrial control, simulation, and automated test equipment. Each channel can be independently configured for current or voltage output, offering flexibility for various application requirements.
- Model
- Abaco Systems / VMIC VMIVME-4120-000
- Calibration
- Available on request
- Price
- $3,499
- RFQ ref
- VMIVME-4120-000
This unit
The Abaco Systems / VMIC VMIVME-4120-000 is a 16-channel Digital-to-Analog (D/A) output board for VMEbus systems. It delivers high-resolution 12-bit analog outputs configurable via jumper selection for either voltage or current operation. The board is housed in a double-height 6U Eurocard form factor and complies with VMEbus specification ANSI/IEEE STD 1014-1987 and IEC 821 and 297.
All 16 channels settle to 1 LSB within 1.7 ms maximum, supporting both default and fast refresh rates to accommodate demanding control and simulation requirements.
Technical Specifications
Analog Output Characteristics- 16 channels, 12-bit resolution
- Maximum settling time to 1 LSB: 1.7 ms (voltage and current)
- Refresh rates: 588 Hz (default, settling to 0.01 percent) or 1,600 Hz fast mode (settling to 0.2 dB or 2.3 percent) Voltage Output Ranges (Jumper-Selectable)
- Unipolar: 0 to +5 V, 0 to +10 V
- Bipolar: ±2.5 V, ±5.0 V, ±10.0 V
- Total error: ±0.05 percent of full-scale range
- Output impedance: 0.33 Ω
- Output load current: 5 mA maximum at full accuracy
- Monotonic over full temperature range
- Short-circuit protection: indefinite to common; momentary to ±25 V
- Accepts straight binary and offset binary codes Current Output Ranges (Jumper-Selectable)
- 4 to 20 mA, 0 to 20 mA, 5 to 25 mA (additional ranges: 4 to 12 mA, 0 to 10 mA, 5 to 15 mA)
- Nonlinearity: 0.01 percent of span
- Initial offset error: 7 µA
- Offset versus temperature: 0.0005 percent of span/°C
- Initial span error: 0.05 percent of span
- Span error versus temperature: 0.0025 percent of span/°C
- Load resistance: 600 Ω maximum at 20 mA; 480 Ω maximum at 25 mA Interfaces and Power
- VME P1 and P2 connectors (VMEbus)
- Output connector: P3 (32-pin DIN) front panel
- Power: 2.5 A typical at +5 VDC; 4.0 A maximum at +5 VDC
- Reset behavior: All outputs disconnected at power-up or reset; current outputs set to minimum selected range value
Key Features
- Jumper-configurable voltage or current outputs eliminate circuit board redesign
- Multiple selectable ranges provide flexibility across industrial control, test automation, and simulation platforms
- Guaranteed monotonicity ensures predictable D/A conversion across temperature extremes
- Dual refresh rates balance update speed with settling accuracy
Typical Applications Industrial process control, automated test equipment, hardware-in-the-loop simulation, multi-channel instrumentation.
Compatibility & Integration Designed for VMEbus-based systems requiring ANSI/IEEE STD 1014-1987 and IEC 821 and 297 compliance. Supports address modifier codes for nonprivileged and supervisory short I/O operations.
Specifications
| Parameter | Value |
|---|---|
| Voltage / Current Range | ±10.0 V (bipolar), 0 to +10 V (unipolar), 0 to 20 mA, 4 to 20 mA |
Abaco Systems / VMIC VMIVME-4120-000 — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Abaco Systems / VMIC VMIVME-4120-000. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.
Abaco Systems / VMIC VMIVME-4120-000 price
This Abaco Systems / VMIC VMIVME-4120-000 is listed at $3,499. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Abaco Systems / VMIC VMIVME-4120-000 calibration cost
NIST-traceable calibration for the Abaco Systems / VMIC VMIVME-4120-000 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →