Acromag AVME9510-i Multifunction Analog and Digital I/O Board

Acromag VME Modules. Voltage / Current Range: ±10V, ±10V; Analog Output: ±2.5V, ±5V, 0–10V; Isolation: 250V AC / 354V DC continuous, 0–5V, Analog Input: 0–10V, Accuracy: 0.04% of FSR, Channel: to-channel rejection: 71 dB.

Model
Acromag AVME9510-i
Calibration
Available on request
Price
$750
RFQ ref
AVME9510-i
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Acromag AVME9510-i is a multifunction analog and digital I/O board for VMEbus systems, combining analog input, analog output, and digital I/O on a single card. The -i suffix denotes optocoupler isolation of field I/O from the VMEbus, mitigating ground loops and transient signal effects. It supports 16 differential or 32 single-ended analog inputs with 12-bit resolution, two analog outputs, and 32 bidirectional digital I/O points - ideal for data acquisition and control applications in space-constrained VME environments.


Technical Specifications

Analog Input

  • 16 differential or 32 single-ended channels

  • 12-bit A/D resolution

  • Input ranges: 0–10V unipolar; ±5V, ±10V bipolar

  • Programmable gain: 1, 2, 4, 8

  • Conversion rate: 32 µS per channel

  • Maximum throughput: 31.25 kHz (single channel); 1 kHz (32 channels)

  • System accuracy: 0.04% of FSR

  • Input overvoltage protection: ±32V continuous

  • CMRR and channel-to-channel rejection: 71 dB

  • RFI resistance: <0.25% of FSR @ 10 V/m (27, 151, 467 MHz)

  • Gain and offset temperature coefficients: 50 ppm/°C, 24 ppm/°C maximum Analog Output

  • 2 channels, non-isolated voltage output

  • 12-bit D/A resolution

  • Output ranges: ±2.5V, ±5V, ±10V, 0–5V, 0–10V

  • System accuracy: 0.025% of FSR

  • Settling time: 6 µS to 0.01% of FSR for 20V step

  • Continuous short-circuit protection Digital I/O

  • 32 bidirectional I/O points configured as four 8-bit ports VMEbus & Isolation

  • VME64 compliance (C.1, October 1985; IEC 821–1987)

  • A24/A16:D16/D08 DTB slave with Read-Modify-Write support

  • Address modifiers: 29H, 2DH, 39H, 3DH

  • 1 kbyte memory map; jumper-configurable base address

  • Field I/O isolation: 250V AC / 354V DC continuous; 1500V AC surge withstand (60 s)


Key Features



  • High-resolution 12-bit A/D and D/A converters

  • Optocoupler isolation eliminates ground loops and protects against transients

  • Flexible analog input configurations support differential or single-ended measurement

  • Fast conversion rate and high throughput for real-time acquisition

  • Programmable gain simplifies signal conditioning

  • Monotonic D/A outputs with tight settling time

  • Overvoltage protection on analog inputs


Typical Applications



  • Industrial data acquisition on VMEbus systems

  • Process control and monitoring

  • Test and measurement systems requiring mixed-signal I/O

  • Equipment where electrical isolation is critical


Compatibility & Integration Manufactured in the USA by Acromag, Inc. Supports standard and short address space configurations in VMEbus crates with memory space allocation from 1 MB to 8 MB per IP module in carrier boards.

Specifications

ParameterValue
Voltage / Current Range±10V, ±10V
Analog Output±2.5V, ±5V, 0–10V
Isolation250V AC / 354V DC continuous, 0–5V, Analog Input: 0–10V

Acromag AVME9510-i — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Acromag AVME9510-i. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Acromag AVME9510-i price

This Acromag AVME9510-i is listed at $750. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Acromag AVME9510-i calibration cost

NIST-traceable calibration for the Acromag AVME9510-i is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →