Burleigh WA-2000 Wavemeter Junior
Burleigh Wavelength Meters. Accuracy: ± 0.02 cm⁻¹, Resolution: 0.001 nm.
- Model
- Burleigh WA-2000
- Calibration
- Available on request
- Price
- $2,770
- Status
- In stock
- RFQ ref
- WA-2000
This unit
The Burleigh WA-2000 Wavemeter Junior is a compact, cost-effective instrument for precise laser wavelength measurement using Michelson interferometer technology. It delivers absolute wavelength measurements across the UV-to-near-infrared spectrum with high accuracy and resolution. The unit features an intuitive digital interface and durable construction suitable for research laboratories and industrial environments.
A collimated laser beam input couples to the optical engine, with wavelength values displayed on an integrated digital readout. Serial communication ports enable data logging and remote system integration.
Technical Specifications
- Wavelength Range: 400 nm to 1800 nm
- Accuracy: ± 0.02 cm⁻¹
- Resolution: 0.001 nm
- Measurement Type: Absolute wavelength
- Technology: Michelson Interferometer
- Input: Collimated laser beam
- Output: Digital display; serial data output (RS-232)
- Power: Standard AC input
Key Features
- Compact form factor for benchtop or rack-mount deployment
- Lightweight design for transport and placement flexibility
- Real-time wavelength readings via integrated digital display
- Minimal control panel with power, measurement, and configuration functions
- Serial interface for automated measurement logging and system control
Typical Applications
- Laser wavelength characterization in spectroscopy
- Production line wavelength verification
- Research applications requiring absolute wavelength measurement
- Industrial quality assurance and process monitoring
Compatibility & Integration The WA-2000 Junior accepts collimated beams from laser sources operating within its 400–1800 nm range. Beam quality, power level, and collimation directly influence measurement performance. Instruments equipped with serial communication support integration into automated measurement systems and external data logging platforms.
Specifications
| Parameter | Value |
|---|---|
| Wavelength Range | 400 nm to 1800 nm |
Burleigh WA-2000 — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Burleigh WA-2000. Calibration covers absolute wavelength accuracy at multiple reference points across the full measurement range, frequency accuracy, wavenumber accuracy, and multi-wavelength channel spacing measurement accuracy. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common Burleigh WA-2000 faults: interferometer alignment drift, reference etalon or HeNe laser end-of-life, InGaAs detector sensitivity loss, fiber input connector damage. Fizeau interferometer-based instruments (Agilent 86120B/86122A/C) most commonly develop interferometer alignment drift and InGaAs detector degradation over time. Burleigh WA-series scanning Fabry-Perot instruments most commonly fail due to reference HeNe laser end-of-life. Both types are fully repairable with post-repair wavelength accuracy verification.
Burleigh WA-2000 price
This Burleigh WA-2000 is listed at $2,770. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Burleigh WA-2000 calibration cost
NIST-traceable calibration for the Burleigh WA-2000 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers absolute wavelength accuracy at multiple reference points across the full measurement range, frequency accuracy, wavenumber accuracy, and multi-wavelength channel spacing measurement accuracy. Turnaround is 1 to 3 business days after receipt. See full calibration details →