Burleigh / Exfo WA-7600 1270-1680nm wavemeter
The Burleigh/Exfo WA-7600 is a high-precision wavemeter designed for accurate wavelength measurement in the 1270-1680nm range. It provides reliable and precise spectral analysis, making it suitable for telecommunications, laser spectroscopy, and optical component testing. This wavemeter ensures dependable performance for various demanding applications requiring wavelength verification and control.
- Model
- Burleigh / Exfo WA-7600
- Calibration
- Available on request
- Price
- $9,980
- Status
- In stock
- RFQ ref
- WA-7600
This unit
The Burleigh/Exfo WA-7600 is a precision wavemeter for absolute wavelength measurement across the 1270–1680 nm band using scanning Michelson interferometer technology. Built-in HeNe laser calibration ensures traceability to recognized standards and accounts for all factors influencing measurement accuracy. The instrument simultaneously measures wavelengths and individual power levels of up to 256 discrete optical signals, making it essential for DWDM system validation, laser spectroscopy, and optical component characterization in telecommunications and R&D environments.
Technical Specifications
Wavelength Range: 1270 nm to 1680 nm (178 THz to 236 THz)
Absolute Wavelength Accuracy: ±0.3 ppm; ±0.3 pm guaranteed at 3σ confidence (≥99.6%)
Spectral Resolution: 30 pm
Display Resolution: 0.0001 nm
Optical Input Sensitivity: −40 dBm (0.1 µW) for 1270–1600 nm; −30 dBm for 1600–1680 nm
Maximum Input Level: +18 dBm
Optical Dynamic Range: >35 dB SNR for channels spaced ≥100 GHz
Power Linearity: ±0.3 dB
Power Uncertainty: ±0.5 dB (±30 nm from 1310 nm and 1550 nm)
Power Display Resolution: 0.01 dB
Simultaneous Measurement Capacity: Up to 256 discrete optical signals
Optical Input: 9/125 µm single-mode fiber
Warm-up Time: 7 minutes
Key Features
Automatic channel spacing and OSNR calculations
Discriminates DWDM channels at 100 GHz, 50 GHz, and 25 GHz spacing
Benchtop or rack-mounted configuration
Operating humidity: ≤90% R.H. at +40°C (non-condensing)
Typical Applications
DWDM system performance monitoring and channel measurement
Telecommunications R&D, manufacturing, network validation, and maintenance
Laser wavelength verification and spectroscopic analysis
Optical component spectral characterization
Compatibility & Integration
Communication interfaces: GPIB, RS-232, floppy disk drive, VGA monitor port, parallel printer port
Optical interface: Universal Interface (EUI) connector adapters available separately
Dimensions: 133 mm H × 432 mm W × 419 mm D
Burleigh / Exfo WA-7600 — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Burleigh / Exfo WA-7600. Calibration covers absolute wavelength accuracy at multiple reference points across the full measurement range, frequency accuracy, wavenumber accuracy, and multi-wavelength channel spacing measurement accuracy. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common Burleigh / Exfo WA-7600 faults: interferometer alignment drift, reference etalon or HeNe laser end-of-life, InGaAs detector sensitivity loss, fiber input connector damage. Fizeau interferometer-based instruments (Agilent 86120B/86122A/C) most commonly develop interferometer alignment drift and InGaAs detector degradation over time. Burleigh WA-series scanning Fabry-Perot instruments most commonly fail due to reference HeNe laser end-of-life. Both types are fully repairable with post-repair wavelength accuracy verification.
Burleigh / Exfo WA-7600 price
This Burleigh / Exfo WA-7600 is listed at $9,980. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Burleigh / Exfo WA-7600 calibration cost
NIST-traceable calibration for the Burleigh / Exfo WA-7600 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers absolute wavelength accuracy at multiple reference points across the full measurement range, frequency accuracy, wavenumber accuracy, and multi-wavelength channel spacing measurement accuracy. Turnaround is 1 to 3 business days after receipt. See full calibration details →