LeCroy WaveJet 312 Digital Oscilloscope 100MHz, 2 Channel

Lecroy Digital Oscilloscopes. Bandwidth: 100 MHz, Channels: 2 Analog, Sample Rate: 1 GS/s.

Model
Lecroy WaveJet 312
Calibration
Available on request
Price
$2,979
Status
In stock
RFQ ref
WaveJet 312
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The LeCroy WaveJet 312 is a 100 MHz, 2-channel digital oscilloscope engineered for circuit testing, design verification, and signal debugging. It delivers 1 GS/s real-time sampling with equivalent-time capability up to 100 GS/s, 500 kpts memory depth per channel, and 8-bit vertical resolution across a 2 mV/div to 10 V/div sensitivity range. The instrument combines portable form factor with benchtop performance, offering 26 automatic measurements, advanced triggering modes including edge, pulse width, period, and TV triggers, plus waveform math and FFT analysis.


A 7.5" color TFT display (640 × 480 VGA) provides clear signal visualization. Peak Detect mode captures transients as narrow as 1 ns. Timebase spans 5 ns/div to 50 s/div with 50 ppm accuracy.


Multiple acquisition modes

Peak Detect, Equivalent-time Sampling, Roll Mode, and averaging up to 256 runs - adapt to diverse measurement scenarios. Input coupling options include GND, DC 1 MΩ, AC 1 MΩ, and DC 50 Ω with 400 V CAT I maximum input rating. The BNC probe interface features Probe Sense Ring technology for automatic probe attenuation detection.


Includes one PP010 probe per channel. Vertical DC gain accuracy is ±(1.5% + 0.5% of full scale). A 6-digit frequency counter displays continuously.


Technical Specifications



  • Bandwidth: 100 MHz

  • Channels: 2 Analog

  • Real-time Sample Rate: 1 GS/s

  • Equivalent-time Sample Rate: Up to 100 GS/s

  • Interleaved Sample Rate: Up to 2 GS/s

  • Memory Depth: 500 kpts/channel

  • Vertical Resolution: 8-bit

  • Vertical Sensitivity: 2 mV/div to 10 V/div (1 MΩ); 2 mV/div to 2 V/div (50 Ω)

  • Vertical DC Gain Accuracy: ±(1.5% + 0.5% of full scale)

  • Input Impedance: 1 MΩ ±1.5% || 16 pF; 1 MΩ ±1.5% || 20 pF; 50 Ω ±1.5%

  • Input Coupling: GND, DC 1 MΩ, AC 1 MΩ, DC 50 Ω

  • Bandwidth Limiters: 20 MHz, 200 MHz

  • Maximum Input Voltage: 400 V CAT I; 5 Vrms (50 Ω)

  • Timebase Range: 5 ns/div to 50 s/div

  • Timebase Accuracy: 50 ppm typical


Key Features



  • Edge, Pulse Width, Period, Pulse Count, and TV triggering

  • Peak Detect acquisition captures 1 ns glitches

  • Equivalent-time Sampling, Roll Mode, and averaging up to 256 runs

  • 26 automatic measurements: frequency, period, rise/fall time, duty cycle, overshoot, pulse width, RMS, peak-peak, integral, and more

  • Waveform Math: Sum, Difference, Product, FFT

  • 6-digit frequency counter (always displayed)

  • 7.5" color TFT LCD (VGA 640 × 480 pixels)

  • BNC connectors with Probe Sense Ring auto-detection

  • Includes one PP010 probe per channel


Connectivity



  • Front-panel USB port for screen image capture

  • Rear-panel USB 1.1 for remote control and printing

  • Optional GPIB interface (WJ-A-GPIB)

  • Optional 10/100Base-T Ethernet (WJ-A-LAN)

  • Compatible with LeCroy ScopeExplorer software


Typical Applications Design debug, signal integrity analysis, protocol verification, and field troubleshooting across general-purpose analog circuit development.

Lecroy WaveJet 312 — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Lecroy WaveJet 312. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Lecroy WaveJet 312 price

This Lecroy WaveJet 312 is listed at $2,979. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Lecroy WaveJet 312 calibration cost

NIST-traceable calibration for the Lecroy WaveJet 312 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →