Teledyne LeCroy WaveSurfer 3054 Oscilloscope, 4 Channel, 500MHz
Teledyne LeCroy Digital Oscilloscopes. Bandwidth: 500 MHz, Accuracy: ±10 ppm (>, Resolution: 8 bits.
- Model
- Teledyne LeCroy WaveSurfer 3054
- Calibration
- Available on request
- Price
- $7,479
- Status
- In stock
- RFQ ref
- WaveSurfer 3054
This unit
The Teledyne LeCroy WaveSurfer 3054 is a 500 MHz, 4-channel digital oscilloscope engineered for signal analysis across laboratory, field service, and production environments. Built around a 10.1-inch capacitive touchscreen with MAUI interface, it delivers intuitive touch operation and efficient debugging workflows. The instrument combines real-time and repetitive acquisition modes with advanced triggering - including edge, width, pattern, TV, runt, and slew rate detection - plus anomaly detection, History Mode for waveform playback, and WaveScan search functionality.
Technical Specifications
Analog Acquisition- Bandwidth: 500 MHz
- Sample rate (single-shot): 2 GS/s; 4 GS/s interleaved
- Sample rate (repetitive): 50 GS/s
- Record length: 10 Mpts per channel (all channels)
- Acquisition modes: Real Time, Roll, RIS (Random Interleaved Sampling), Sequence (segmented memory up to 1,000 segments, 1 μs minimum intersegment time)
- Timebase: 1 ns/div to 50 s/div (Real Time); 1 ns/div to 10 ns/div (RIS)
- Timebase accuracy: ±10 ppm (>1 ms interval)
- Pre-trigger delay: 0 to 100% of Full Scale
- Post-trigger delay: 0 to 10,000 Divisions
- Hold-off: 10 ns to 20 s or 1 to 100,000,000 events Vertical System
- Vertical resolution: 8 bits; up to 11 bits with ERES (Enhanced Resolution)
- Sensitivity (1 MΩ): 1 mV/div to 10 V/div
- Sensitivity (50 Ω): 1 mV/div to 1 V/div
- DC gain accuracy: ±1.5% (Full Scale, Offset at 0 V, >5 mV/div); ±2.5% (<5 mV/div)
- Bandwidth limiters: 20 MHz, 200 MHz
- Input impedance (1 MΩ): 1 MΩ ± 2.0% || 16 pF
- Input impedance (50 Ω): 50 Ω ± 2.0%
- Maximum input voltage (1 MΩ): 400 V (DC + Peak AC ≤10 kHz)
- Maximum input voltage (50 Ω): 5 VRMS, ±10 V Peak
- Channel isolation: ≥52 dB (DC to 100 MHz) Triggering System
- Modes: Normal, Auto, Single, Stop
- Sources: Any input channel, External, Ext/5, or line
- Trigger coupling: AC, DC, LF Reject, HF Reject
- Trigger types: Edge, Width, Logic (Pattern), TV (NTSC, PAL, SECAM; HDTV 720p, 1080i, 1080p), Runt, Slew Rate
- Internal trigger level range: ±4.1 Divisions
- External trigger level range (Ext): ±610 mV
- External trigger level range (Ext/5): ±3.05 V
Key Features
- Fast waveform update rate for real-time signal monitoring
- Dual-impedance vertical channels (1 MΩ and 50 Ω selectable)
- Sequence acquisition with up to 1,000 segmented memory blocks
- Comprehensive input coupling options (AC, DC, GND)
- History Mode enables waveform playback and trending analysis
- WaveScan advanced search and find for anomaly detection
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | DC to 500 MHz | Voltage / Current Range: 1 mV/div to 10 V/div (1 MΩ) |
Teledyne LeCroy WaveSurfer 3054 — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Teledyne LeCroy WaveSurfer 3054. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.
Teledyne LeCroy WaveSurfer 3054 price
This Teledyne LeCroy WaveSurfer 3054 is listed at $7,479. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Teledyne LeCroy WaveSurfer 3054 calibration cost
NIST-traceable calibration for the Teledyne LeCroy WaveSurfer 3054 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →