Agilent/Keysight 08564-60028

Agilent / Keysight Spectrum Analyzers. Frequency Range: 30 Hz to 40 GHz, Voltage / Current Range: 1.8 A rms max, 115 Vac: 90–140 V rms, 3.2 A RMS max; 230 VAC: 180–250 V RMS.

Model
Keysight 08564-60028
Calibration
Available on request
Price
$455
RFQ ref
08564-60028
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Agilent/Keysight 08564-60028 is an accessory that extends the measurement and analysis capabilities of the Agilent 8564E portable millimeter spectrum analyzer. It enables precision signal analysis, component testing, and interference detection across millimeter and microwave frequencies with selectable resolution bandwidth and integrated measurement personalities for specialized applications.


Technical Specifications

Frequency Coverage

  • Continuous sweep: 30 Hz to 40 GHz (preselected above 2.75 GHz) Resolution Bandwidth

  • Fast digital RBWs: 1 Hz, 3 Hz, 10 Hz, 30 Hz, 100 Hz

  • Selectable RBW range: 1 Hz to 1 MHz

  • Selectivity: RBW ≥ 300 Hz (–60 dB/–3 dB BW ratio) Counter & Timebase

  • Precision timebase with 1 Hz counter resolution

  • Marker count accuracy: ±(marker freq × freq ref accuracy + 2 Hz × N)

  • Accuracy at 1 GHz: ±225 Hz (5-minute warm-up)

  • Delta count accuracy: ±(delta freq × freq ref accuracy + 4 Hz × N)

  • Counter resolution: 1 Hz to 1 MHz (selectable) Environmental & Ruggedness

  • MIL-T-28800 rugged construction

  • Operating temperature: –10°C to +55°C

  • Non-operating temperature: –51°C to +71°C

  • Humidity rating: 95% @ 40°C for 5 days

  • Rain resistance: Drip-proof at 16 liters/hour/sq. ft.

  • Altitude: 15,000 ft. (operating), 50,000 ft. (non-operating)

  • Pulse shock: 30g for 11 ms half sine

  • Transit drop: 8-inch drop on six faces and eight corners Power Requirements (associated analyzer)

  • 115 VAC: 90–140 V rms, 3.2 A rms max, 47–440 Hz

  • 230 VAC: 180–250 V rms, 1.8 A rms max, 47–66 Hz


Key Features



  • Adjacent Channel Power (ACP) measurements

  • Channel Power and Carrier Power measurement modes

  • Occupied Bandwidth Percentage capability

  • Time-gated measurements for transient analysis

  • Measurement personalities for digital radio and phase noise analysis


Typical Applications



  • RF and microwave signal monitoring

  • Component and subsystem testing

  • Electromagnetic interference detection and characterization

  • Frequency domain analysis in field and lab environments


Compatibility & Integration Designed exclusively for integration with the Agilent/Keysight 8564E Portable Millimeter Spectrum Analyzer.

Specifications

ParameterValue
Frequency Range30 Hz to 40 GHz | Voltage / Current Range: 1.8 A rms max, 115 Vac: 90–140 V rms, 3.2 A RMS max
230 VAC180–250 V RMS

Keysight 08564-60028 — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Keysight 08564-60028. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Keysight 08564-60028 price

This Keysight 08564-60028 is listed at $455. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Keysight 08564-60028 calibration cost

NIST-traceable calibration for the Keysight 08564-60028 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →