Agilent/Keysight 11715A
Agilent / Keysight RF Signal Sources. Voltage: 100–120 Vac (±5%.
- Model
- Agilent / Keysight 11715A
- Calibration
- Available on request
- Price
- $1,076
- Status
- In stock
- RFQ ref
- 11715A
This unit
The Agilent/Keysight 11715A AM/FM Test Source is a precision RF signal generator engineered for modulation analyzer verification and receiver measurement applications. It produces flat, low-distortion amplitude-modulated and frequency-modulated RF signals across multiple frequency bands using a low-noise VCO, double-balanced mixer, and digital divider architecture.
Technical Specifications
Frequency Outputs- Fixed output: 560 MHz carrier (crystal-derived, residual FM 400 kHz peak with distortion < 0.025%
- Deviation linearity: ±0.1% to 100 kHz modulation rates; typically ±2.5% to 10 MHz rates
- Residual FM: < 3 Hz rms (50 Hz–3 kHz post-detection bandwidth) Amplitude Modulation (AM)
- Modulation depth: Up to 99% available (11–13.5 MHz range)
- Distortion: < 0.1% at 95% AM; < 0.05% THD at 50% AM (20 Hz–100 kHz modulation)
- Depth linearity: ±0.2% variation up to 99% AM
- Residual AM: < 0.01% rms (50 Hz–3 kHz post-detection bandwidth) Power & Environment
- Input voltage: 100–120 Vac (±5%, -10%) or 220–240 Vac (±5%, -10%) at 48–440 Hz
- Power dissipation: 40 VA maximum
- Operating temperature: 0–55°C
- Storage temperature: -55–75°C Physical
- Dimensions: 102 mm H × 212 mm W × 444 mm D
- Net weight: 4.4 kg (shipping: 6.5 kg)
Key Features
- Four separate RF outputs for multi-point test configurations
- External modulation source input for custom waveform injection
- Wideband DC-coupled design ensures deviation linearity across wide modulation rates
- Low residual AM and FM minimize measurement uncertainty
- Meets MIL STD 461A (CE03, RE02, CS01, CS02, RS03 at 1 V/m), VDE 0871 (Level B), and CISPR 11
Typical Applications
- Calibration and performance verification of modulation analyzers
- AM/FM receiver testing and adjustment
- Signal source for RF test benches requiring stable, low-distortion modulated carriers
Compatibility & Integration Designed for performance tests and adjustments of modulation analysis equipment. Compact 19-inch compatible form factor integrates into standard laboratory and production test setups.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 11 MHz to 13.5 MHz (AM and FM) |
| 560 MHz (fixed) | Voltage / Current Range | −10%) |
Agilent / Keysight 11715A — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Agilent / Keysight 11715A. Calibration covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common Agilent / Keysight 11715A faults: YIG oscillator failure (no output or loss of lock), step attenuator wear (output drops or steps at set attenuation), ALC loop failure (uncontrolled output power), I/Q modulator assembly failure. HP/Agilent 836xx series most common faults are YIG oscillator failure and step attenuator contact wear causing output steps or drops at specific attenuation settings. Keysight E4428C/E4438C units most commonly develop ALC loop failure and I/Q modulator assembly faults. YIG oscillator replacement and attenuator service are stocked repairs.
Agilent / Keysight 11715A price
This Agilent / Keysight 11715A is listed at $1,076. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Agilent / Keysight 11715A calibration cost
NIST-traceable calibration for the Agilent / Keysight 11715A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. Turnaround is 1 to 3 business days after receipt. See full calibration details →