Agilent/Keysight 11792A

The Agilent/Keysight 11792A is a general purpose cable designed for interconnecting RF and microwave components and systems. It ensures reliable signal transmission with minimal loss and reflection. Ideal for test and measurement setups.

Model
Agilent / Keysight 11792A
Calibration
Available on request
Price · starting from
$250
Status
In stock
RFQ ref
11792A
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Agilent/Keysight 11792A is an RF power sensor module engineered for precision power measurements spanning 50 MHz to 26.5 GHz. It integrates with the Agilent 8902A measuring receiver and, when paired with the 11793A microwave converter, extends measurement capability to the full upper frequency limit. The module delivers accurate characterization of AM, FM, and phase modulation across its operating range with exceptional linearity and return loss performance.


Technical Specifications

Frequency Range: 50 MHz to 26.5 GHz Power Measurement Range:

  • Standard: +30 dBm (1 W) to -20 dBm (10 μW); down to -100 dBm with specific configurations

  • IF Synchronous Detector: +10 dBm to -117 dBm (2.5 MHz ≤ fc ≤ 1300 MHz); +5 dBm to -105 dBm (1300 MHz ≤ fc ≤ 12.4 GHz); +5 dBm to -100 dBm (12.4 GHz ≤ fc ≤ 18.0 GHz); +5 dBm to -95 dBm (18.0 GHz ≤ fc ≤ 26.5 GHz)

  • IF Average Detector: +10 dBm to -90 dBm (2.5 MHz ≤ fc ≤ 1300 MHz); +5 dBm to -80 dBm (1300 MHz ≤ fc ≤ 12.4 GHz); +5 dBm to -75 dBm (12.4 GHz ≤ fc ≤ 18.0 GHz) Connector: 3.5 mm (m); Type-N option (Option 001, limited to 18 GHz) Impedance: 50 ohms Return Loss (Input SWR):

  • <1.10 (f ≤ 2.0 GHz)

  • <1.28 (2.0 GHz < f ≤ 18.0 GHz)

  • <1.40 (18.0 GHz < f ≤ 26.5 GHz)

  • 1.05 nominal Linearity: ±0.02 dB within range; ±0.02 dB per range change from reference ± 1 digit Calibration: Individually determined and traceable to U.S. National Bureau of Standards. System accuracy improvement available with Option 050 on 8902A receiver.


Key Features



  • Measures AM, FM, and phase modulation including residuals and incidentals

  • Minimal signal loss and reflection across full frequency span

  • Internal on/off switching controlled by host receiver

  • Compact form factor: 51 mm (H) × 62 mm (W); 0.8 kg net weight

  • Supplied with 925 mm RF cable and 944 mm sensor cable


Compatibility & Integration Designed for the Agilent 8901B modulation analyzer and 8902A measuring receiver. Extended measurement to 26.5 GHz achieved through pairing with the 11793A microwave converter.

Specifications

ParameterValue
Frequency Range50 MHz to 26.5 GHz | Power Range (dBm): '-20 dBm to +30 dBm

Agilent / Keysight 11792A — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Agilent / Keysight 11792A. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Agilent / Keysight 11792A price

This Agilent / Keysight 11792A is listed at $250. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Agilent / Keysight 11792A calibration cost

NIST-traceable calibration for the Agilent / Keysight 11792A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →