Astronics / EADS / Racal 1260-30D Multiplexer VXI Module

The Astronics 1260-30D is a VXI Multiplexer Module designed for versatile signal routing in automated test and measurement systems. This module enables the connection of multiple input signals to a single output, or vice versa, enhancing system flexibility and efficiency.

Model
Astronics / EADS / Racal 1260-30D
Calibration
Available on request
Price
$1,250
Status
In stock
RFQ ref
1260-30D
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Astronics / EADS / Racal 1260-30D is a C-size VXIbus multiplexer module engineered for signal routing and switching in automated test systems. This single-slot module configures as eight independent 1x5 two-wire multiplexer networks, enabling flexible connection of multiple input signals to a common output or vice versa. The 10 MHz bandwidth supports switching up to 250V at 2A, making it suitable for DMM scanning, continuity testing, and general UUT point verification.

Technical Specifications

Module Type: Multiplexer VXI Module

Form Factor: C-Size, Single-Slot

Configuration: Eight 1x5 two-wire multiplexer networks

Bandwidth: 10 MHz

Switching Capability: Up to 250V, 2A

Relay Coil Current Monitoring: Built-in confidence checking

Key Features

Configurable multiplexer architecture supporting eight independent 1x5 networks

Relay coil current monitoring for relay operation verification

Mounting holes associated with each channel for user-supplied component integration

Message-based and register-based VXIbus control interfaces

Smart Card (Option 01) control support via Local Bus (LBus) communication

Typical Applications

Scanning and routing multiple UUT test points to a Digital Multimeter

Continuity and resistance measurement automation

Multi-channel signal multiplexing in test benches

General signal path selection in measurement systems

Compatibility & Integration Designed for VXI platforms with full VXIbus compatibility. The module integrates with Option 01 Smart Card controllers via Local Bus for distributed system architectures. Heritage from Racal Instruments brand ensures proven reliability in production test environments.

Specifications

ParameterValue
Frequency Range10 MHz | Voltage / Current Range: 2 ADC/AAC, 250 VDC/VAC

Astronics / EADS / Racal 1260-30D — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Astronics / EADS / Racal 1260-30D. Calibration covers all module-specific parameters per manufacturer datasheet, output accuracy and linearity, frequency accuracy, and VXI register and trigger bus compliance. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Astronics / EADS / Racal 1260-30D faults: relay contact wear, DAC/ADC drift, VXI backplane connector oxidation. Common faults include relay contact wear, DAC or ADC gain drift, and VXI backplane edge connector oxidation. Most modules are repaired at the component level with full post-repair verification in a C-size or D-size mainframe.

Astronics / EADS / Racal 1260-30D price

This Astronics / EADS / Racal 1260-30D is listed at $1,250. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Astronics / EADS / Racal 1260-30D calibration cost

NIST-traceable calibration for the Astronics / EADS / Racal 1260-30D is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers all module-specific parameters per manufacturer datasheet, output accuracy and linearity, frequency accuracy, and VXI register and trigger bus compliance. Turnaround is 1 to 3 business days after receipt. See full calibration details →