Astronics / EADS / Racal 1260-45B High-Density Switch Matrix (Option 01 or 01T Compatible)
Astronics / EADS / Racal VXI Modules. Voltage: 300 VDC or ACrms (terminal-terminal or terminal-ch, Current: 1 ADC or ACrms per channel, Bandwidth: 25 MHz (4×16 and 4×32 configs).
- Model
- Astronics / EADS / Racal 1260-45B
- Calibration
- Available on request
- Price
- $1,950
- Status
- In stock
- RFQ ref
- 1260-45B
This unit
The Astronics/EADS/Racal 1260-45B is a high-density signal routing switch matrix housed in a C-size, single-slot VXIbus module. It delivers configurable two-wire matrix topologies - most notably two 4×32 configurations - supporting applications requiring flexible signal path selection across eleven possible matrix arrangements. The module handles switching loads up to 300 VDC/ACrms and 1 A per channel, with maximum path resistance of 500 mΩ and isolation exceeding 2 GΩ.
Technical Specifications Electrical Performance
Maximum switchable voltage: 300 VDC or ACrms (terminal-terminal or terminal-chassis)
Maximum switchable current: 1 ADC or ACrms per channel
Maximum switchable power: 30 WDC, 62.5 VA per channel
Path resistance: ≤500 mΩ
Isolation: >2 GΩ AC Performance (50 Ω)
Capacitance (Hi to Lo): <50 pF open, <80 pF closed
Bandwidth: 25 MHz (4×16 and 4×32 configs), 20 MHz (4×64 config), 10 MHz (16×16 config)
Crosstalk at 1 MHz: <-50 dB Physical & Environmental
Form factor: C-size, single-slot VXIbus module
Weight: 3.07 lb (1.38 kg) without Option 01; 3.35 lb (1.51 kg) with Option 01
Cooling: 1.0 liters/sec airflow, 0.05 mm H₂O backpressure (2.0 liters/sec and 0.2 mm H₂O with Option 01S/T)
Key Features
Eleven configurable matrix topologies; 1260-45B optimized for dual 4×32 two-wire matrices
Non-latching guard relays at matrix row inputs - safety feature that opens signal paths on power loss
Latching relay bypass option via jumpers for continuous signal routing
IDC ribbon cable or discrete wire crimp connectors; one mating connector set included
Typical Applications
Automated test equipment signal switching and routing
Multi-channel signal path selection in production and validation environments
Applications requiring DC and low-frequency AC signal switching with isolation and low crosstalk
Compatibility & Integration The 1260-45B operates with Option 01 (native command set) or Option 01T (SCPI command set) smart controllers, providing both message-based and register-based control interfaces for integration into VXIbus test systems.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | DC to 25 MHz | Voltage / Current Range: 1 ADC/ACrms per channel, 300 VDC/ACrms |
Astronics / EADS / Racal 1260-45B — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Astronics / EADS / Racal 1260-45B. Calibration covers all module-specific parameters per manufacturer datasheet, output accuracy and linearity, frequency accuracy, and VXI register and trigger bus compliance. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common Astronics / EADS / Racal 1260-45B faults: relay contact wear, DAC/ADC drift, VXI backplane connector oxidation. Common faults include relay contact wear, DAC or ADC gain drift, and VXI backplane edge connector oxidation. Most modules are repaired at the component level with full post-repair verification in a C-size or D-size mainframe.
Astronics / EADS / Racal 1260-45B price
This Astronics / EADS / Racal 1260-45B is listed at $1,950. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Astronics / EADS / Racal 1260-45B calibration cost
NIST-traceable calibration for the Astronics / EADS / Racal 1260-45B is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers all module-specific parameters per manufacturer datasheet, output accuracy and linearity, frequency accuracy, and VXI register and trigger bus compliance. Turnaround is 1 to 3 business days after receipt. See full calibration details →