Fluke / Wavetek / Datron 1396 50 MHz Arbitrary Waveform Synthesizer
The Fluke/Wavetek/Datron 1396 is a 50 MHz Arbitrary Waveform Synthesizer. It provides stable, high-precision waveforms for a variety of testing and measurement applications. This synthesizer offers flexible waveform generation with user-defined arbitrary waveforms and standard functions.
- Model
- Fluke/Wavetek/Datron 1396
- Calibration
- Available on request
- Price
- $2,100
- Status
- In stock
- RFQ ref
- 1396
This unit
The Fluke/Wavetek/Datron 1396 is a 50 MHz arbitrary waveform synthesizer engineered as a single-slot C-size VXIbus module for flexible signal generation across test and measurement applications. It combines standard function generator capabilities with user-defined arbitrary waveform creation, delivering 12-bit vertical resolution and support for up to 131,072 waveform points (524,288 optional). SCPI compatibility enables dynamic instrument configuration and simplified programming.
Technical Specifications Waveform Generation
Arbitrary waveforms: 12-bit resolution, 5 to 131,072 points (524,288 optional), up to 50 MS/s sampling
Standard waveforms: sine to 20 MHz, square to 25 MHz, triangle/ramp/haversine/random/(sin x)/x/DC from 1 mHz to 2 MHz
Linked sequencing: up to 4096 segments with loop counts from 1 to 1,048,576 or continuous operation
Independently programmable segment frequencies as integer divisors of master sampling rate
Trigger-based or continuous sequence start; Word Serial command or trigger event advance conditions Frequency and Timing
Master clock: 50 MHz in CW mode with internal clock
Raster mode: mantissa 25 MHz to 50 MHz with 5-digit resolution
Built-in frequency sweep and frequency list function for custom sweep/hop sequences
Internal CLK10 signal drives frequency synthesizer and trigger timer Amplitude and Output
Main output into 50Ω: 15 mV to 15 Vp-p; into >10 kΩ: 30 mV to 30 Vp-p
Output impedance: 50Ω nominal; protected to ±20 Vdc
Amplitude and offset resolution: 3.5 digits; accuracy: ±1% of setting
DC offset range: ±7.5 V into 50Ω, ±15 V into >10 kΩ (peak + offset ≤ 7.5 V into 50Ω)
Filtering: 20 MHz 4-pole Bessel and 20 MHz 7-pole 6-zero elliptic Modulation & Outputs
AM and suppressed carrier modulation with internal or external modulation input
16-bit digital output
Key Features
SCPI programming interface for rapid integration
Flexible sequence and loop control up to 4096 linked segments
High-resolution arbitrary waveform capability with optional extended memory
Integrated sweep and frequency-list functions
Typical Applications
Component and subsystem functional testing
Analog filter characterization
Signal simulation and modulation testing
Compatibility & Integration VXIbus C-size single-slot module with SCPI command set for integration into automated test systems.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 1 mHz to 50 MHz | Voltage / Current Range: 15 mV to 15 Vp-p into 50Ω |
Fluke/Wavetek/Datron 1396 — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Fluke/Wavetek/Datron 1396. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.
Fluke/Wavetek/Datron 1396 price
This Fluke/Wavetek/Datron 1396 is listed at $2,100. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Fluke/Wavetek/Datron 1396 calibration cost
NIST-traceable calibration for the Fluke/Wavetek/Datron 1396 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →