The Amplifier Research 150A220 is a solid-state RF amplifier with a frequency range of 10 kHz to 220 MHz. It delivers a minimum of 150 watts of output power, offering excellent gain, linearity, and reliability for various applications including EMC testing, communications, and scientific research.
- Model
- Amplifier Research 150A220
- Calibration
- Available on request
- Price
- $10,500
- Status
- In stock
- RFQ ref
- 150A220
This unit
The Amplifier Research 150A220 is a solid-state, linear broadband RF amplifier engineered for laboratory and test environments demanding instantaneous bandwidth across a wide frequency span. Built on MOSFET technology, this 150 W rated amplifier delivers up to 250 W typical output at 3 dB compression while maintaining ±1.5 dB flatness across its operating range. The unIt has 53 dB minimum gain with continuous 18 dB adjustment capability, allowing precise power control from 1.0 mW input.
Complete thermal and over-current protection, combined with 100% mismatch tolerance at rated output power, ensures operation survives any source and load impedance combination without damage, foldback, shutdown, or oscillation. With harmonic distortion of −20 dBc (10 kHz to 125 MHz) and −30 dBc (125 MHz to 250 MHz), the amplifier meets demanding spectral purity requirements. RF rise time of 3 ns maximum and a typical third-order intercept point of 60 dBm support high-fidelity signal conditioning.
The 150A220 accepts 50 Ω sources with 1.5:1 maximum VSWR and configures in multiple form factors, including rack-mount (M1) and BNC-input (M6) variants. Remote control via 25-pin subminiature D connector and optional computer interface (CP2001, CP3000 accessories) enable automated test sequences and system integration.
Technical Specifications
- Frequency Range: 10 kHz to 220 MHz instantaneously
- Rated Output Power: 150 watts
- Input for Rated Output: 1.0 mW maximum
- Power Output @ 3 dB Compression: 250 W typical, 150 W minimum
- Power Output @ 1 dB Compression: 200 W typical, 150 W minimum
- Gain (maximum setting): 53 dB minimum
- Gain Adjust (continuous range): 18 dB minimum
- Flatness: ±1.5 dB maximum
- Harmonic Distortion at 150 W: −20 dBc (10 kHz–125 MHz); −30 dBc (125 MHz–250 MHz)
- Third-Order Intercept Point: 60 dBm typical
- RF Rise Time (10% to 90%): 3 ns maximum
- Input Impedance: 50 Ω, 1.5:1 VSWR maximum
- Mismatch Tolerance: 100% of rated power without damage across all source/load impedance magnitudes and phases
Key Features
- Solid-state MOSFET design for linear amplification
- Integrated thermal and over-current protection
- Total mismatch tolerance at rated output power
- Broadband operation without tuning
- Continuous gain adjustment for precise output control
Interfaces & Configuration
- RF Input: Type N female (Type BNC female on M6 variant)
- RF Output: Type N female
- Remote Control: 25-pin subminiature D connector
- Computer Interface: CP2001 and CP3000 accessories available
- Standard dimensions: 50.7 cm × 34.0 cm × 55.0 cm; 47 kg
- Rack-mount option (M1): 48.3 cm × 31.2 cm × 52.3 cm; 34 kg
Compatibility & Integration The 150A220 integrates with Amplifier Research control accessories CP2001 and CP3000 for remote and automated operation in multi-instrument test systems.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 10 kHz to 220 MHz | Power Range (dBm): 60 dBm (third-order intercept point, typical) |
Amplifier Research 150A220 — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Amplifier Research 150A220. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.
Amplifier Research 150A220 price
This Amplifier Research 150A220 is listed at $10,500. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Amplifier Research 150A220 calibration cost
NIST-traceable calibration for the Amplifier Research 150A220 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →