Agilent / Keysight 83006A Microwave System Amplifier, 10 MHz to 26.5 GHz

Agilent / Keysight RF Amplifiers. Frequency Range: 10 MHz to 26.5 GHz, Power Range (dBm): +18 dBm (10 MHz–10 GHz); +13 dBm min (10 MHz–20 GHz); P1dB >13 dBm to 20 GHz, Voltage / Current Range: -12V @ 50mA, +12V @ 450mA.

Model
Agilent / Keysight 83006A
Calibration
Available on request
Price
$1,922
Status
In stock
RFQ ref
83006A
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Keysight 83006A is a microwave system amplifier engineered to recover signal losses and boost RF/microwave signal strength across ultra-broadband frequencies from 10 MHz to 26.5 GHz. This compact, off-the-shelf amplifier delivers minimum 20 dB small-signal gain while maintaining controlled gain flatness - ±5 dB from 10 MHz to 5 GHz and ±3 dB from 5 GHz to 26.5 GHz. Its single broadband design eliminates the need for multiple narrow-band amplifiers, crossover networks, or multiple bias supplies, making it ideal for simplified ATE system integration.


Technical Specifications



  • Frequency Range: 10 MHz to 26.5 GHz

  • Small Signal Gain: ≥20 dB minimum

  • Gain Flatness: ±5 dB (10 MHz–5 GHz); ±3 dB (5–26.5 GHz)

  • Output Power: +18 dBm (10 MHz–10 GHz typical); +13 dBm minimum (10 MHz–20 GHz at 1 dB compression)

  • P1dB: >13 dBm to 20 GHz

  • Noise Figure: 8 dB (0.1–18 GHz); <13 dB (0.01–0.1 GHz and 20–26.5 GHz)

  • Harmonics: –25 dBc (10 MHz–11 GHz)

  • Third Order Intercept (TOI): 30 dBm at 2 GHz

  • Input SWR: 2.6:1

  • Output SWR: 2.8:1 (10 MHz–18 GHz)

  • Reverse Isolation: –65 dB typical

  • Survival Input Power: +23 dBm maximum

  • Impedance: 50 Ω

  • Power Dissipation: 6 W


Electrical Bias & Connectors



  • Bias Requirements: +12 V @ 450 mA; –12 V @ 50 mA (external power supply)

  • Compatible Power Supplies: Keysight 87421A (25 W); Keysight 87422A (70 W)

  • RF Connectors: 3.5 mm (female)

  • Bias Cable: 2 meters standard


Physical Specifications



  • Weight: 0.64 kg (1.4 lbs)


Integration & Related Components Pair with Keysight 83036C directional detector (10 MHz–26.5 GHz) or 87300C coupler with 8474C detector (1–26.5 GHz) for signal leveling and monitoring in automated test systems.

Specifications

ParameterValue
Frequency Range10 MHz to 26.5 GHz | Power Range (dBm): '+15 dBm to +20 dBm output | Voltage / Current Range: '-12 V @ 50 mA, +12 V @ 450 mA

Agilent / Keysight 83006A — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Agilent / Keysight 83006A. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Agilent / Keysight 83006A price

This Agilent / Keysight 83006A is listed at $1,922.38. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Agilent / Keysight 83006A calibration cost

NIST-traceable calibration for the Agilent / Keysight 83006A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →