Agilent/Keysight 8349A

Agilent / Keysight RF Amplifiers. Frequency Range: 2 to 20 GHz.

Model
Agilent / Keysight 8349A
Calibration
Available on request
Price
$1,019
Status
In stock
RFQ ref
8349A
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Agilent/Keysight 8349A is a broadband microwave amplifier delivering consistent gain and leveled output power across 2 to 20 GHz. Built on a multi-stage GaAs FET architecture, It has minimum 15 dB small-signal gain with 80 mW leveled output power and ±1.25 dB flatness from 2 to 18.6 GHz, typically extending to 20 GHz. The amplifier achieves a 1 dB compression point of +21 dBm nominal and third-order intercept of +33 dBm nominal, making it suitable for dynamic range extension and signal boosting in test and measurement systems.


Noise figure remains below 13 dB typical. Fast pulse transmission capability - rise/fall time under 10 ns and input-to-output delay under 8 ns - supports pulsed signal applications. Harmonics are controlled to -30 to -20 dBc across the band, with non-harmonic spurious content at -55 dBc or better.


Technical Specifications



  • Frequency Range: 2 to 20 GHz

  • Gain: >15 dB (full band); minimum 15 dB small signal at -5 dBm input

  • Output Power (Leveled): 80 mW (+19 dBm), 2 to 18.6 GHz, typically to 20 GHz

  • Output Power (Unleveled): 100 mW (+20 dBm)

  • Power Flatness (Leveled): ±1.25 dB

  • 1 dB Compression Point: +21 dBm nominal

  • Noise Figure: <13 dB typical

  • Third Order Intercept: +33 dBm nominal

  • Input SWR: ≤2.8

  • Output SWR (Leveled): ≤2.5

  • Maximum Input Power: +27 dBm RF; ±10 V DC

  • Harmonics: -20 dBc or better (2.0 to <11.0 GHz at +20 dBm output); -30 dBc or better (11.0 to 20.0 GHz at +20 dBm output)

  • Non-Harmonic Spurious: ≤-55 dBc

  • Pulse Rise/Fall Time: <10 ns typical

  • Pulse Delay (Input to Output): <8 ns typical

  • RF Connectors: Type N female

  • Dimensions: 133 mm (H) × 214 mm (W) × 366 mm (D)

  • Weight: 7 kg net; 14 kg shipping


Key Features



  • Multi-stage GaAs FET design for wide-band amplification

  • Leveled output maintains power flatness across frequency sweep

  • Low harmonics and spurious performance

  • Fast pulse response for time-domain measurements


Typical Applications



  • Signal boosting in test and measurement setups

  • Scalar network analyzer dynamic range extension

  • RFI susceptibility testing

  • Antenna efficiency and pattern measurements

  • Use with fixed or swept frequency sources


Compatibility & Integration Designed for interfacing with HP microwave sources including 8350 or 8620C sweep oscillators, 8340A/8341A synthesized sweepers, and 8672A or 8673 synthesized signal generators. Compatible with HP 8755C, 8736A, and 8757A scalar network analyzers when used with sweep oscillators for extended measurement capability.

Specifications

ParameterValue
Frequency Range2.0 GHz to 20 GHz | Power Range (dBm): '+20 dBm to +17 dBm output (100 mW to 50 mW) | Voltage / Current Range: 100, 120, 200, or 240 VAC (±10%)

Agilent / Keysight 8349A — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Agilent / Keysight 8349A. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Agilent / Keysight 8349A price

This Agilent / Keysight 8349A is listed at $1,019. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Agilent / Keysight 8349A calibration cost

NIST-traceable calibration for the Agilent / Keysight 8349A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →