Agilent/Keysight 8349A
Agilent / Keysight RF Amplifiers. Frequency Range: 2 to 20 GHz.
- Model
- Agilent / Keysight 8349A
- Calibration
- Available on request
- Price
- $1,019
- Status
- In stock
- RFQ ref
- 8349A
This unit
The Agilent/Keysight 8349A is a broadband microwave amplifier delivering consistent gain and leveled output power across 2 to 20 GHz. Built on a multi-stage GaAs FET architecture, It has minimum 15 dB small-signal gain with 80 mW leveled output power and ±1.25 dB flatness from 2 to 18.6 GHz, typically extending to 20 GHz. The amplifier achieves a 1 dB compression point of +21 dBm nominal and third-order intercept of +33 dBm nominal, making it suitable for dynamic range extension and signal boosting in test and measurement systems.
Noise figure remains below 13 dB typical. Fast pulse transmission capability - rise/fall time under 10 ns and input-to-output delay under 8 ns - supports pulsed signal applications. Harmonics are controlled to -30 to -20 dBc across the band, with non-harmonic spurious content at -55 dBc or better.
Technical Specifications
- Frequency Range: 2 to 20 GHz
- Gain: >15 dB (full band); minimum 15 dB small signal at -5 dBm input
- Output Power (Leveled): 80 mW (+19 dBm), 2 to 18.6 GHz, typically to 20 GHz
- Output Power (Unleveled): 100 mW (+20 dBm)
- Power Flatness (Leveled): ±1.25 dB
- 1 dB Compression Point: +21 dBm nominal
- Noise Figure: <13 dB typical
- Third Order Intercept: +33 dBm nominal
- Input SWR: ≤2.8
- Output SWR (Leveled): ≤2.5
- Maximum Input Power: +27 dBm RF; ±10 V DC
- Harmonics: -20 dBc or better (2.0 to <11.0 GHz at +20 dBm output); -30 dBc or better (11.0 to 20.0 GHz at +20 dBm output)
- Non-Harmonic Spurious: ≤-55 dBc
- Pulse Rise/Fall Time: <10 ns typical
- Pulse Delay (Input to Output): <8 ns typical
- RF Connectors: Type N female
- Dimensions: 133 mm (H) × 214 mm (W) × 366 mm (D)
- Weight: 7 kg net; 14 kg shipping
Key Features
- Multi-stage GaAs FET design for wide-band amplification
- Leveled output maintains power flatness across frequency sweep
- Low harmonics and spurious performance
- Fast pulse response for time-domain measurements
Typical Applications
- Signal boosting in test and measurement setups
- Scalar network analyzer dynamic range extension
- RFI susceptibility testing
- Antenna efficiency and pattern measurements
- Use with fixed or swept frequency sources
Compatibility & Integration Designed for interfacing with HP microwave sources including 8350 or 8620C sweep oscillators, 8340A/8341A synthesized sweepers, and 8672A or 8673 synthesized signal generators. Compatible with HP 8755C, 8736A, and 8757A scalar network analyzers when used with sweep oscillators for extended measurement capability.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 2.0 GHz to 20 GHz | Power Range (dBm): '+20 dBm to +17 dBm output (100 mW to 50 mW) | Voltage / Current Range: 100, 120, 200, or 240 VAC (±10%) |
Agilent / Keysight 8349A — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Agilent / Keysight 8349A. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.
Agilent / Keysight 8349A price
This Agilent / Keysight 8349A is listed at $1,019. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Agilent / Keysight 8349A calibration cost
NIST-traceable calibration for the Agilent / Keysight 8349A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →