Hart Scientific Fluke 1524 Reference Thermometer (Temperature Measurement)

Fluke / Hart Scientific Temperature Test Equipment. Current: 1 mA (0–400 Ω), Sample rate: 1 reading/second standard.

Model
Fluke / Hart Scientific 1524
Calibration
Available on request
Price
$3,050
RFQ ref
1524
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Fluke 1524 Reference Thermometer is a dual-channel, handheld instrument for high-accuracy temperature measurement across laboratory and field environments. It accepts Platinum Resistance Thermometers (PRTs), Resistance Temperature Detectors (RTDs), thermocouples, and thermistors, delivering measurement ranges from -200 °C to 2315 °C depending on sensor type. The instrument employs current reversal technique to eliminate thermal EMFs, achieving accuracy to ±0.002 °C for thermistors and ±0.011 °C for PRTs while remaining insensitive to ambient temperature fluctuations.


Technical Specifications

Measurement Capabilities

  • Input channels: 2

  • PRT/RTD range: -200 °C to 1000 °C [-328 °F to 1832 °F]; accuracy ±0.011 °C; resolution 0.001°

  • Thermocouple range: -200 °C to 2315 °C [-328 °F to 4199 °F]; accuracy ±0.24 °C (J, K, L, M types); resolution 0.01°

  • Thermistor range: -50 °C to 150 °C [-58 °F to 302 °F]; accuracy ±0.002 °C; resolution 0.001°

  • Millivolt range: -10 mV to 75 mV; accuracy ±(0.005% + 5 µV)

  • Resistance ranges: 0–400 Ω, 200–50 kΩ, 50–500 kΩ

  • Excitation current: 1 mA (0–400 Ω), 10 µA (0–50 kΩ), 2 µA (50–500 kΩ) Sampling and Logging

  • Sample rate: 1 reading/second standard; 1 reading/0.3 seconds fast mode

  • Data logging: 15,000 measurements; configurable intervals from 1 reading/hour to 1 reading/0.3 seconds

  • Real-time clock with date/time stamping; Document on Demand function stores up to 25 readings with statistics Display and Interface

  • 128×64 backlit LCD graphic display with real-time dual-channel trend plotting

  • RS-232 serial interface; 9940 I/O ToolKit software included; optional LogWare II software available Power and Environmental

  • Internal: 3 AA batteries (>20 hours operation)

  • External: 12 VDC Universal Power Supply (included)

  • Operating range: -10 °C to 60 °C; best accuracy 13 °C to 33 °C


Key Features



  • Current reversal eliminates thermal EMFs for precision measurements

  • Dual simultaneous temperature channels reduce measurement time

  • Configurable logging intervals support both continuous monitoring and spot sampling

  • Rugged design validated under temperature extremes and vibration stress


Typical Applications Calibration laboratories, process control verification, thermal validation testing, equipment commissioning.


Compatibility & Integration RS-232 serial connection enables integration with laboratory data acquisition systems and calibration software suites.

Specifications

ParameterValue
Voltage / Current Range12 VDC external

Fluke / Hart Scientific 1524 — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Fluke / Hart Scientific 1524. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Fluke / Hart Scientific 1524 price

This Fluke / Hart Scientific 1524 is listed at $3,050. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Fluke / Hart Scientific 1524 calibration cost

NIST-traceable calibration for the Fluke / Hart Scientific 1524 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →