Amplifier Research 200T1G3A
The Amplifier Research 200T1G3A is a solid-state RF amplifier designed for various applications. It operates in the frequency range of 1 GHz to 3 GHz and delivers an output power of 200 watts. This amplifier is suitable for EMC testing, communications, and general laboratory use.
- Model
- Amplifier Research 200T1G3A
- Calibration
- Available on request
- Price
- $22,000
- Status
- In stock
- RFQ ref
- 200T1G3A
This unit
The Amplifier Research 200T1G3A is a self-contained, air-cooled broadband traveling wave tube (TWT) microwave amplifier delivering 200 W CW output across 0.8 GHz to 2.8 GHz instantaneously. This benchtop-configured unit features 53 dB minimum gain with 35 dB continuous adjustment range and operates at 1.0 mW input for rated output. Purpose-built for susceptibility testing and RF laboratory applications, it combines high instantaneous bandwidth with precise gain control and built-in output power foldback protection.
The amplifier accepts AM, FM, and pulse modulation, supports video pulse widths down to 0.05 μs, and includes IEEE-488 (GPIB) remote control as standard. Type N connectors serve RF input, output, and sample ports; forced-air cooling and 19-inch rack compatibility enable flexible deployment in test benches or integrated systems.
Technical Specifications
RF Performance- Frequency Range: 0.8 GHz to 2.8 GHz (instantaneous)
- Output Power (CW): 200 W minimum
- Linear Output Power (1 dB compression): 50 W minimum
- Power Gain (maximum): 53 dB minimum
- Gain Adjustment: 35 dB continuous range
- Input for Rated Output: 1.0 mW maximum
- Input Impedance: 50 Ω, VSWR 2.0:1 maximum
- Output Impedance: 50 Ω, VSWR 2.5:1 typical Noise & Distortion
- Noise Power Density: −77 dBm/Hz typical, −72 dBm/Hz maximum
- Harmonic Distortion: −6 dBc typical, −3 dBc maximum Frequency Response
- ±12 dB maximum across 0.8 GHz – 2.8 GHz
- ±1.2 dB maximum across 1.0 GHz – 2.0 GHz Pulse Characteristics
- Minimum Pulse Width: 0.05 μs
- Maximum PRF: 100 kHz
- RF Rise/Fall Time: 30 ns maximum (10% to 90%)
- Pulse Delay: 300 ns maximum
- Pulse Width Distortion: ±30 ns maximum Power Supply
- Input: 190 – 260 Vac, 50/60 Hz, single phase
- Consumption: 200 W minimum, 242 W nominal, 2.5 kVA maximum
Key Features
- Mismatch tolerance operates without damage across any load impedance
- Output power foldback protection when reflected power exceeds 40 W
- VSWR protection included as standard
- Modulation support: AM, FM, and pulse
- Forced-air self-contained cooling with rear-panel airflow
Compatibility & Integration
- IEEE-488 (GPIB) interface for remote operation
- Type N female connectors (input, output, sample port)
- DB-15 female interlock connector
- Video monitoring via BNC connector
- 19-inch rack-mount capable
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 0.8 GHz to 2.8 GHz | Power Range (dBm): −77 dBm/Hz to −72 dBm/Hz (noise power density) | Voltage / Current Range: 190 – 260 Vac, 50/60 Hz, single phase |
Amplifier Research 200T1G3A — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Amplifier Research 200T1G3A. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.
Amplifier Research 200T1G3A price
This Amplifier Research 200T1G3A is listed at $22,000. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Amplifier Research 200T1G3A calibration cost
NIST-traceable calibration for the Amplifier Research 200T1G3A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →