Keithley 2100/100 – 6½-Digit USB Multimeter
The Keithley 2100/100 is a 6½-digit USB multimeter offering high accuracy and resolution for a variety of measurement applications. It features a broad range of measurement functions, including DC voltage, AC voltage, DC current, AC current, resistance, frequency, and temperature. Its USB interface allows for easy connectivity to a computer for data logging and analysis. The 2100/100 is ideal for benchtop testing, automated test systems, and data acquisition applications where precision and reliability are essential.
- Model
- Keithley 2100/100
- Calibration
- Available on request
- Price
- $550
- Status
- In stock
- RFQ ref
- 2100/100
This unit
The Keithley 2100/100 is a 6½-digit USB multimeter delivering precision DC and AC measurements across voltage, current, resistance, frequency, and temperature. With 0.0038% basic DC voltage accuracy on the 10V range and 0.013% resistance accuracy on the 10kΩ range, this instrument serves R&D engineers, test engineers, scientists, and students in benchtop and automated test environments.
Technical Specifications Measurement Functions
DC and AC voltage (True RMS) to 750V
DC and AC current (True RMS) to 3.000000A
Resistance from 100Ω to 100MΩ
Frequency measurement 3 Hz to 300 kHz
RTD temperature with ±0.1°C accuracy (-100°C to +100°C) and ±0.2°C (-200°C to +630°C) Performance
50 triggered readings/second at 6½ digits via USB
Over 2000 readings/second at 4½ digits into internal buffer
Input protection: 1000V (2-wire mode)
Input bias current: <30pA at 25°C Temperature Measurement Supports PT100, D100, F100, PT385, and PT3916 RTDs with 0.001°C resolution across two ranges. Maximum lead resistance: 12Ω per lead at 1mA pulsed sensor current. Mathematical Functions RATIO, percentage, Min/Max, NULL, limits, mX+b, dB, and dBm calculations.
Key Features
TMC-compliant USB 2.0 interface with Agilent 34401A command emulation for plug-and-play integration
5x7 dot matrix VFD display with three-color annunciators and selectable front/rear inputs
Rugged construction with removable rubber bumpers for bench, portable, or stacking applications
Sturdy carrying handle for field use
1 PLC or continuous trigger measurement modes
Software Integration Included KI-Tool application enables real-time charting and graphing of measurements without programming.
Typical Applications Component characterization, calibration verification, manufacturing test, thermal monitoring, and automated test system integration.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 3 Hz to 300 kHz | Voltage / Current Range: 1.000000 A to 3.000000 A (AC current), 100.0000 mV to 750 V (AC voltage) |
Keithley 2100/100 — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Keithley 2100/100. Calibration covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common Keithley 2100/100 faults: blown input fuse, worn input jacks, display segment failure, relay contact wear on bench DMMs. Common faults include worn input jacks (banana socket contact wear on the mA and COM terminals), blown input fuses (especially the 440 mA HRC fuse), and display segment failures. Keithley 2000/2001/2002 bench DMMs commonly develop relay contact wear affecting resistance accuracy after extended service.
Keithley 2100/100 price
This Keithley 2100/100 is listed at $550. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Keithley 2100/100 calibration cost
NIST-traceable calibration for the Keithley 2100/100 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. Turnaround is 1 to 3 business days after receipt. See full calibration details →