HP / Agilent 3311A FUNCTION GENERATOR

The HP/Agilent 3311A is a function generator capable of producing sine, square, and triangle waveforms. It features a frequency range from 0.1 Hz to 1 MHz and offers adjustable amplitude and DC offset. This instrument is suitable for a variety of electronic testing and signal generation applications.

Model
HP / Agilent 3311A
Calibration
Available on request
Price
$351
Status
In stock
RFQ ref
3311A
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The HP/Agilent 3311A is a compact function generator delivering sine, square, triangle, and positive pulse waveforms across seven frequency decades from 0.1 Hz to 1 MHz. Engineered for lab validation, system integration, and education, it combines pushbutton convenience with independent amplitude and DC offset control.

Technical Specifications Frequency and Waveforms

Frequency range: 0.1 Hz to 1 MHz (seven decade ranges)

Waveforms: Sine, square, triangle, positive pulse

Dial accuracy: ±5% of full scale

Square wave time axis symmetry error: ±2% maximum to 100 kHz Main Output

Amplitude: 10 Vp-p into 600 Ω; 20 Vp-p open circuit

Amplitude control: Continuously variable with >30 dB attenuation range

Output impedance: 600 Ω (nominal)

DC offset: Independently adjustable up to ±10 V DC (open circuit) or ±5 V DC (into 600 Ω)

Maximum combined Vp-p + Vdc without clipping: ±10 V (open circuit); ±5 V (into 600 Ω) Pulse Output

TTL compatible; >3 V positive amplitude (open circuit)

Duty cycle: 13.5% to 16.5% of total period

Transition times: 10:1 on any frequency range

Input: 0.0 V to -10 V ±2 V linear ramp produces >10:1 frequency increase

Input impedance: 10 kΩ ±10% in parallel with <60 pF Electrical

Power requirements: 100/120/220/240 V AC, ±10%/+5% switchable, 48 Hz to 66 Hz

Power consumption: ≤12 VA

Key Features

Output isolation up to ±500 V relative to instrument case (external supply)

Compact form factor: 89 mm H × 159 mm W × 248 mm D; 1.5 kg net weight

Operating temperature: 0°C to 55°C (specifications +15°C to +35°C)

Standard BNC main output; separate TTL pulse output

Typical Applications Component characterization, frequency response measurement, signal simulation, TTL logic verification, and educational demonstrations in electronics labs.

Compatibility & Integration Rack mount kits available: 10851A (single unit); 10852A (dual units).

Specifications

ParameterValue
Frequency Range0.1 Hz to 1 MHz | Voltage / Current Range: ±5 V (into 600 Ω)
Pulse output>3 V positive, 100/120/220/240 VAC
Main output10 Vp-p into 600 Ω, 20 Vp-p open circuit
DC offset±10 V (open circuit)

HP / Agilent 3311A — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the HP / Agilent 3311A. Calibration covers output frequency accuracy, output amplitude accuracy at 50 ohm and Hi-Z load, DC offset accuracy, symmetry and duty cycle accuracy, and arbitrary waveform sample rate accuracy. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common HP / Agilent 3311A faults: BNC output connector wear, output amplifier failure from short-circuit drive, display and keypad membrane switch wear, DDS or DAC failure on 33250A. HP 33120A and Agilent 33220A most common fault is BNC output connector wear from repeated cable insertions. Output amplifier failure on the HP 33120A typically results from sustained short-circuit drive. Agilent 33250A DDS and high-speed DAC failures are rare but require component-level repair and post-repair amplitude verification across the full 80 MHz range.

HP / Agilent 3311A price

This HP / Agilent 3311A is listed at $350.98. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

HP / Agilent 3311A calibration cost

NIST-traceable calibration for the HP / Agilent 3311A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers output frequency accuracy, output amplitude accuracy at 50 ohm and Hi-Z load, DC offset accuracy, symmetry and duty cycle accuracy, and arbitrary waveform sample rate accuracy. Turnaround is 1 to 3 business days after receipt. See full calibration details →