Photonetics 3642HE15 TUNICS-SW TUNABLE LASER SOURCE

PHOTONETICS Tunable Laser Sources. Accuracy: ±0.04 nm absolute.

Model
PHOTONETICS 3642HE15
Calibration
Available on request
Price
$8,830
Status
In stock
RFQ ref
3642HE15
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Photonetics 3642HE15 TUNICS-SW is a tunable laser source delivering continuous mode-hop-free operation across the 1460–1595 nm band. Built on an external cavity architecture with invar construction, It has wavelength accuracy to ±0.04 nm and tuning repeatability of ±0.005 nm without requiring temperature stabilization. The integrated wavelength referencing system enables fast, independent wavelength measurement and control, eliminating reliance on external meters.


Technical Specifications



  • Wavelength Range: 1460–1595 nm (full range); 1500–1570 nm at 0 dBm; 1460–1600 nm at −3 dBm

  • Output Power: 0 dBm (1460–1470 nm), 3 dBm (1470–1490 nm), 6 dBm (1490–1530 nm), 8 dBm (1530–1595 nm), up to +10 dBm

  • Wavelength Accuracy: ±0.04 nm absolute

  • Tuning Repeatability: ±0.005 nm (typical)

  • Tuning Speed: 1–100 nm/s (adjustable, continuous sweep)

  • Spontaneous Emission: >40 dB or >45 dB

  • Relative Intensity Noise: −145 dB/Hz (typical)

  • Optical Connector: FC/APC

  • Fiber Type: Single Mode

  • Laser Safety Classification: Class 1M


Key Features



  • External cavity design with patented TUNICS cavity and dihedral rear reflector ensures self-aligned resonator stability

  • Active mode-hop-free control maintains continuous operation across full wavelength range

  • Invar optical head construction delivers zero-thermal-expansion stability with instant start-up and minimal power consumption

  • Internal wavelength referencing system provides precise, real-time wavelength measurement and control


Typical Applications Telecommunications testing, optical system characterization, and research environments requiring stable, tunable narrowband sources.


Compatibility & Integration Remote control via RS-232 and GPIB (IEEE-488.1). Dimensions: 448 × 370 × 133 mm (W × D × H). Weight: 12.5 kg.

Specifications

ParameterValue
Power Range (dBm)Up to +10 dBm | Wavelength Range: 1260 nm to 1640 nm

PHOTONETICS 3642HE15 — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the PHOTONETICS 3642HE15. Calibration covers wavelength accuracy at 5 or more points across the full tuning range, mode-hop-free range, output power flatness, linewidth, and side-mode suppression ratio (SMSR). All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common PHOTONETICS 3642HE15 faults: output power drift, mode hops, fiber pigtail connector damage, wavelength inaccuracy. Common faults include output power drift after extended use, mode hops at specific wavelengths, and fiber pigtail connector damage. Full alignment and piezo calibration typically restore performance to spec.

PHOTONETICS 3642HE15 price

This PHOTONETICS 3642HE15 is listed at $8,830. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

PHOTONETICS 3642HE15 calibration cost

NIST-traceable calibration for the PHOTONETICS 3642HE15 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers wavelength accuracy at 5 or more points across the full tuning range, mode-hop-free range, output power flatness, linewidth, and side-mode suppression ratio (SMSR). Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents