Agilent/Keysight 81608A Tunable Laser Module (1370–1510 nm)

The Agilent/Keysight 81608A is a tunable laser source designed for high-performance optical testing and measurement applications. It provides precise wavelength control and stable output power, making it suitable for characterizing optical components and systems. Its narrow linewidth and low spontaneous emission ensure accurate and reliable test results.

Model
Agilent / Keysight 81608A
Calibration
Available on request
Price
$25,789
Status
In stock
RFQ ref
81608A
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Keysight 81608A Tunable Laser Module delivers precise wavelength control and stable optical output across the 1370–1510 nm band. This source combines narrow linewidth, low spontaneous emission, and excellent wavelength repeatability, making it ideal for coherent transmission experiments and manufacturing-floor component testing. The module integrates into the 8164B Lightwave Measurement System mainframe and operates with user-adjustable output power down to 0 dBm, supported by the N7700A photonic application suite.


Technical Specifications

Wavelength Performance

  • Tuning range: 1370–1510 nm (Option 114)

  • Absolute accuracy (static): ±5 pm typical

  • Absolute accuracy (sweeping): ±10 pm typical

  • Wavelength repeatability: ±1.5 pm typical (two-way sweeps to 200 nm/s)

  • Sweep speed: up to 200 nm/s bidirectional Optical Output

  • Peak output power: >+12 dBm typical

  • Output level range: >±12 dBm

  • User-adjustable power down to 0 dBm

  • Signal-to-spontaneous emission ratio: ≥75 dB/nm typical

  • Power stability: ±0.03 dB over 24 hours Physical & Environmental

  • Dimensions: 16 × 14 × 10 in

  • Weight: 25 lbs

  • Storage/shipping temperature: -40 °C to +70 °C

  • Output connector: PMF with angled contact

  • Front panel: two BNC connectors (input/output); maximum ±6 V external voltage rated


Key Features



  • Narrow linewidth with low spontaneous emission for accurate, reliable measurements

  • Long-term stability enhanced by built-in gas cell and self-adjustment

  • Bidirectional sweep capability maintains ±1.5 pm repeatability at 200 nm/s

  • Dry air or nitrogen operation recommended in high water-absorption regions (1350–1420 nm); optional dry air connector available

  • Back-loadable design fits 8164B mainframe bottom slot


Typical Applications



  • Coherent transmission system characterization

  • Component testing on manufacturing floors

  • Spectral measurements via N7700A software integration


Compatibility & Integration Module integrates into Keysight 8164B Lightwave Measurement System mainframe; supported by N7700A photonic application suite. Laser classified per IEC 60825-1; compliant with 21 CFR 1040.10 per Laser Notice No. 50 (June 24, 2007).

Agilent / Keysight 81608A — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Agilent / Keysight 81608A. Calibration covers wavelength accuracy at 5 or more points across the full tuning range, mode-hop-free range, output power flatness, linewidth, and side-mode suppression ratio (SMSR). All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Agilent / Keysight 81608A faults: output power drift, mode hops, fiber pigtail connector damage, wavelength inaccuracy. Common faults include output power drift after extended use, mode hops at specific wavelengths, and fiber pigtail connector damage. Full alignment and piezo calibration typically restore performance to spec.

Agilent / Keysight 81608A price

This Agilent / Keysight 81608A is listed at $25,789. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Agilent / Keysight 81608A calibration cost

NIST-traceable calibration for the Agilent / Keysight 81608A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers wavelength accuracy at 5 or more points across the full tuning range, mode-hop-free range, output power flatness, linewidth, and side-mode suppression ratio (SMSR). Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents