Agilent 81642A Tunable Laser Source 1510-1670nm Range Option 072 **CALIBRATED**

Agilent Tunable Laser Sources. Resolution: ** 0.1 pm (equivalent to 12.5 MHz at 1550 nm).

Model
HP 81642A
Calibration
Available on request
Price
$13,480
RFQ ref
81642A
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Agilent 81642A Tunable Laser Source (TLS) with Option 072 is a precision instrument designed for applications requiring a stable and tunable light source within the C- and L- bands of the optical spectrum. This module is optimized for testing optical amplifiers and passive components, particularly in DWDM (Dense Wavelength Division Multiplexing) systems. It features mode-hop-free tuning across its entire wavelength range and offers continuous output power, ensuring consistent performance for critical testing scenarios. The use of Polarization Maintaining Fiber (PMF) with an angled contact connector, as specified by Option 072, helps reduce reflections and spectral ripple, leading to more accurate measurements.

Technical Specifications * Model: Agilent 81642A

  • Option: 072 (Polarization Maintaining Fiber, Angled Contact Output Connector)
  • Wavelength Range: 1510 nm to 1640 nm (Some sources indicate 1510-1670nm or 1510-1640nm)
  • Wavelength Resolution: 0.1 pm (equivalent to 12.5 MHz at 1550 nm)
  • Wavelength Accuracy (absolute): ±0.015 nm
  • Wavelength Repeatability (typical): ±0.5 pm
  • Maximum Output Power: * +7 dBm * > -3 dBm (1510-1640 nm) * > -4.5 dBm (1510 - 1640 nm)
  • Mode-Hop Free Tuning: Yes, over the full wavelength range
  • Tuning Span: Any 50 nm within 1520-1620 nm at flat output power > 2 dBm
  • Spectral Linewidth: * 100 KHz (coherent control off) * > 50 MHz (1520-1620 nm, at maximum flat output power, coherent control on)
  • Optical Power Stability: ±0.01 dB
  • Output Type: High power optical output
  • Fiber Type: Polarization Maintaining Fiber (Panda-Type)
  • Connector Type: Angled Contact (Panda-Type)
  • Extinction Ratio (PMF): 16 dB (typical)
  • Return Loss (with angled connectors, options 022, 072): 60 dB (typical)
  • Output Isolation (typical): 50 dB
  • Built-in Wavelength Control: Yes
  • Built-in Real-time Wavelength Meter: Yes
  • Laser Class: Class Illb according to FDA 21 CFR 1040.10, Class 3A according to IEC 825-1
  • Warm-up Time: < 20 min (immediate operation after boot-up)
  • Recommended Re-calibration Period: 2 years

Environmental and Physical * Operating Temperature: 10 °C to 35 °C

  • Storage Temperature: -40 °C to +70 °C

Compatibility * Mainframe Compatibility: Fits into the bottom slot of the 8164A mainframe. Also compatible with Agilent 8163A/B, 8164A/B, and 8166A/B mainframes and systems.

  • Option 072 Recommendation: Highly recommended over Option 071 (straight contact) to reduce front-panel connector reflections, thereby minimizing interference noise and spectral ripple in the test setup.

Interface and Control * GPIB Interface: Supported, with function codes SH1, AH1, T6, L4, SR1, RL1, PPO, DC2, DTO, CO

  • RS-232C Interface: Max. baud rate: 115,200 bps
  • Parallel Printer Interface: Centronics
  • PC Card Slot: One type I, II, and III compliant with PC Card Standard PCMCIA 2.1/JEIDA 4.1
  • External Keyboard: PS/2 connector
  • Data Storage: Internal Hard Disk Drive (2000 MB ATA), PC and SRAM PC cards Why Choose Aumictech for Agilent 81642A Tunable Laser Source? At Aumictech, we specialize in sourcing and validating high-end optical test and measurement equipment. Whether you need a meticulously calibrated Agilent 81642A Tunable Laser Source for critical DWDM component testing, require precise wavelength stability for advanced research, or need a solid solution for optical amplifier characterization, our team ensures the Agilent 81642A delivers maximum performance for your application.

Specifications

ParameterValue
Power Range (dBm)−3 dBm to +7 dBm
Voltage / Current Range±10%, 100 to 240 Vrms, 280 VA max
Wavelength Range1510 nm to 1640 nm

HP 81642A — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the HP 81642A. Calibration covers wavelength accuracy at 5 or more points across the full tuning range, mode-hop-free range, output power flatness, linewidth, and side-mode suppression ratio (SMSR). All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common HP 81642A faults: output power drift, mode hops, fiber pigtail connector damage, wavelength inaccuracy. Common faults include output power drift after extended use, mode hops at specific wavelengths, and fiber pigtail connector damage. Full alignment and piezo calibration typically restore performance to spec.

HP 81642A price

This HP 81642A is listed at $13,480. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

HP 81642A calibration cost

NIST-traceable calibration for the HP 81642A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers wavelength accuracy at 5 or more points across the full tuning range, mode-hop-free range, output power flatness, linewidth, and side-mode suppression ratio (SMSR). Turnaround is 1 to 3 business days after receipt. See full calibration details →