HP / Agilent 54622D 2+16 Channel, 100 MHz Mixed-Signal Oscilloscope
HP / Agilent Mixed Signal Oscilloscopes (MSO). Bandwidth: 100 MHz, Sample Rate: 400 MSa/s maximum, Resolution: 8-bit.
- Model
- HP / Agilent 54622D
- Calibration
- Available on request
- Price
- $255
- Status
- In stock
- RFQ ref
- 54622D
This unit
The HP/Agilent 54622D is a 2+16 channel mixed-signal oscilloscope delivering simultaneous acquisition of analog and digital signals up to 100 MHz bandwidth. Built for engineers analyzing complex embedded systems, digital interfaces, and multi-protocol designs, this instrument combines 2 analog channels with 16 digital logic channels in a single platform.
Technical Specifications Analog Channels
Bandwidth: 100 MHz
Sample Rate: 400 MSa/s maximum
Vertical Resolution: 8-bit
Vertical Sensitivity: 1 mV to 5 V/div
Vertical Accuracy: ±(0.01% reading ±0.1% screen width) + 40 ps typical (same channel); ±(0.01% reading ±0.1% screen width) ±80 ps typical (channel-to-channel)
Input Impedance: 1 MΩ ±3% with 14 pF
Maximum Input: ±40 V peak CAT I Digital Channels
Channels: 16 (two 8-channel pods)
Sample Rate: 400 MSa/s
Threshold Options: TTL, CMOS, ECL, user-definable (±8.0 V in 10 mV increments)
Input Impedance: 100 kΩ ±2%
Channel-to-Channel Skew: 2 ns typical, 3 ns maximum Acquisition & Memory
Memory Depth: 2 MB/channel standard; 4 MB maximum in single-channel mode
MegaZoom deep memory technology for long, non-repeating signal capture
Time Base: 5 ns/div to 50 s/div
Time Base Resolution: 40 ps
Interpolation: Sin x/x
Display Modes: Vector or dot; high-resolution mode provides up to 12 bits real-time resolution
Vector Processing: 25 million vectors/sec Triggering
Edge, Pulse Width, Pattern, CAN, Duration, I²C, LIN, Sequence, SPI, TV, and USB triggering
Available across all channels Waveform Analysis
Math functions: FFT, subtract, multiply, integrate, differentiate
Key Features
7-inch monochrome CRT display with superior horizontal resolution
Pre-trigger capture (negative delay) greater than 1 screen width or 10 ms; post-trigger (positive delay) up to 500 seconds
Dual-threshold logic pods for flexible digital protocol analysis
Typical Applications Embedded system debugging, serial protocol validation (I²C, SPI, CAN, USB, LIN), mixed-signal verification, digital timing analysis, analog-to-digital signal correlation.
Compatibility & Integration Standard RS-232 and parallel ports; optional GPIB module for remote control and automated data transfer.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | DC to 100 MHz | Voltage / Current Range: ±40 V peak input |
HP / Agilent 54622D — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the HP / Agilent 54622D. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.
HP / Agilent 54622D price
This HP / Agilent 54622D is listed at $255.4. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
HP / Agilent 54622D calibration cost
NIST-traceable calibration for the HP / Agilent 54622D is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →