HP / Agilent 54754A Differential & Single-ended TDR/TDT Module
HP / Agilent Mixed Signal Oscilloscopes (MSO). Channels: ** Two 18 GHz electrical channels with 3.5 mm male, Bandwidth: ** 12.4 GHz or 18 GHz selectable per channel, Resolution: ** 12 bits (15 bits with averaging).
- Model
- HP / Agilent 54754A
- Calibration
- Available on request
- Price
- $2,248
- Status
- In stock
- RFQ ref
- 54754A
This unit
The HP/Agilent 54754A is a differential and single-ended TDR/TDT module for high-speed signal integrity characterization. It performs Time Domain Reflectometry and Time Domain Transmission measurements across both differential and single-ended configurations, enabling precise analysis of impedance discontinuities, propagation delay, and interconnect performance. The module integrates with compatible mainframe oscilloscopes to deliver comprehensive impulse and transmission testing for high-speed digital design and advanced material evaluation.
Technical Specifications
Measurement Modes: Differential TDR, single-ended TDR, differential TDT, single-ended TDT
Channels: Two 18 GHz electrical channels with 3.5 mm male connectors
Bandwidth: 12.4 GHz or 18 GHz selectable per channel; 2.5 GHz trigger channel
Vertical Resolution: 12 bits (15 bits with averaging)
Vertical Accuracy: 0.4%
Characteristic RMS Noise: 0.25 mV at 12.4 GHz; 0.5 mV at 18 GHz
Maximum Input Signal: ±2 Vdc
Step Generators: Two built-in generators supporting 1-port, 2-port common mode, and 2-port differential configurations
Edge Speed: User-selectable
S-Parameter Measurement: Supported with mainframe firmware revision A.06.01 or later and Option 202
Calibration: Built-in TDR/TDT calibration
Distance Resolution: Approximately 1.5 mm in air with 40 GHz probes and normalization (rise time limited)
Key Features
Dual-channel 18 GHz architecture for simultaneous differential and single-ended measurements
Automatic and manual TDR/TDT measurement modes
Advanced waveform processing: FFT, histogram, waveform math, eye pattern, and statistical analysis
Limit testing capability for production validation
12-bit vertical digitization with optional 15-bit averaging mode
Typical Applications
Signal integrity analysis in high-speed interconnects
Impedance discontinuity detection and characterization
Differential pair measurements and validation
PCB material and transmission line characterization
Propagation delay measurement and analysis
Compatibility & Integration The 54754A integrates with the following mainframe oscilloscopes: Agilent/Keysight 54750A, Agilent/HP 83480A, Agilent/HP 86100A/B/C, and Agilent/HP 86100D.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | DC to 18 GHz (channels) |
| 2.5 GHz trigger channel | Voltage / Current Range | ±2 Vdc maximum input |
HP / Agilent 54754A — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the HP / Agilent 54754A. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.
HP / Agilent 54754A price
This HP / Agilent 54754A is listed at $2,248. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
HP / Agilent 54754A calibration cost
NIST-traceable calibration for the HP / Agilent 54754A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →