Fluke 5550A Performance Multi-Product Calibrator

Fluke Calibration Equipment. Voltage: 0 V to ±1020 V, Current: 0 to ±30.2 A, Voltage: 1 mV to 1020 V.

Model
Fluke 5550A
Calibration
Available on request
Price
$32,439
Status
In stock
RFQ ref
5550A
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Fluke 5550A Performance Multi-Product Calibrator is a high-accuracy calibration instrument engineered for calibration laboratories and service centers. It calibrates digital multimeters, oscilloscopes, power meters, and other electrical test equipment with optimized ranges for modern workloads. A 7-inch color touchscreen with intuitive graphical interface and visual connection management guides operators through each calibration task, while improved settling time accelerates multimeter calibration cycles.


Technical Specifications

Electrical Output Ranges:

  • Direct voltage: 0 V to ±1020 V

  • Direct current: 0 to ±30.2 A

  • Alternating voltage: 1 mV to 1020 V, 3 Hz to 500 kHz

  • Alternating current: 10 μA to 30.2 A, 3 Hz to 30 kHz

  • Volt/Hertz: 1000 V at 10 kHz / 330 V at 100 kHz

  • Waveforms: Sine wave, triangle wave, truncated sine wave

  • Resistance: 0 Ω to 1200 MΩ

  • Capacitance: 200 pF to 120 mF

  • Inductance: 12 μH to 12 H

  • Dual output power: 30.9 kW

  • Continuous current output: 30 A (expandable to 6000 A with 52120A amplifier)

  • Oscilloscope bandwidth: 2.1 GHz, 1.1 GHz, or 600 MHz Temperature & Thermocouple Support:

  • Thermocouple types: B, C, E, J, K, L, N, R, S, U, BP, XK

  • Temperature standards: ITS-90, IPTS-68

  • RTD outputs: Pt100 (385/395/3916), Pt200 (385), Pt500 (385), Pt1000 (385), Ni120, Cu10

  • RTD compensation: Off, 2-wire, 4-wire Performance:

  • Frequency uncertainty: <2.5 ppm

  • Phase control: 0.01°

  • Phase lock: Yes

  • Test uncertainty ratio: 4:1 TUR calibrates 5.5-digit multimeters and some 6.5-digit multimeters


Key Features



  • Reverse power protection up to ±300 V peak

  • 7-inch color touchscreen with visual terminal guidance

  • Remote interfaces: USB 2.0, Ethernet (Telnet), RS-232, GPIB

  • Compatible with MET/CAL Calibration Management Software

  • Automatic mains selection: 100 V, 120 V, 220 V, 240 V (±10 %)

  • Max power consumption: 500 VA

  • Operating temperature: 0 °C to 50 °C


Compatibility & Integration Automated calibration workflows via MET/CAL software. RS-232 configured as DTE. Multi-protocol remote command support enables integration with existing calibration management systems.

Specifications

ParameterValue
Frequency Range3 Hz to 500 kHz (AC voltage)
3 Hz to 30 kHz (AC current) | Voltage / Current Range0 V to ±1020 V DC

Fluke 5550A — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Fluke 5550A. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Fluke 5550A price

This Fluke 5550A is listed at $32,439. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Fluke 5550A calibration cost

NIST-traceable calibration for the Fluke 5550A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents