Fluke 6062A/AG – Synthesized Signal Generator
Fluke RF Signal Sources. Model: 6062A/AG.
- Model
- Fluke 6062A/AG
- Calibration
- Available on request
- Price
- $1,550
- Status
- In stock
- RFQ ref
- 6062A/AG
This unit
The Fluke 6062A/AG is a synthesized signal generator engineered for RF testing, communications systems evaluation, and component characterization. It delivers precise frequency synthesis across 100 kHz to 2.1 GHz with output levels spanning +16 dBm to −137 dBm, supported by multiple modulation modes and exceptional spectral purity. The instrument integrates GPIB/IEEE-488 control, making it suitable for both benchtop measurement and automated test environments.
Technical Specifications Frequency & Resolution
100 kHz to 2.1 GHz operating range
10 Hz frequency steps and resolution from 0.1 to 1050 MHz
20 Hz frequency steps and resolution from 1050 to 2100 MHz Output Power
+16 dBm to −137 dBm (0.1 to 1050 MHz)
+13 dBm to −137 dBm (1050 to 2100 MHz)
0.1 dB programmable steps with autoranging 6 dB step attenuator Amplitude Accuracy
±1.5 dB across specified operating ranges
±2.0 dB from +16 to −127 dBm (0.1 to 999.99999 MHz) Modulation
AM, FM, phase, and pulse modulation modes
AM depth: 0 to 99% in 1% increments
FM deviation: 1, 10, 100, and 400 kHz selectable
Phase deviation: 0.10, 1.0, 10.0, and 40.0 radians
Internal modulation oscillator: 400 to 1000 Hz selectable
Pulse modulation: 15 nanosecond rise and fall time (GaAs), ~50% internal duty cycle
External pulse: DC to 16 MHz rates, 0 to 100% duty cycle adjustable Spectral Purity
Non-harmonic spurious: <−60 dBc (0.1 to 1049.99999 MHz)
Non-harmonic spurious: 10 kHz offset)
Harmonics: <−30 dBc
Fixed frequency spurs: <−60 dBc or <−140 dBm (whichever larger) Time Base
Crystal time base with ±0.5 ppm/month ageing rate and ±5 ppm at 25°C
Optional medium-stability or ovenized high-stability time bases
External reference: 1, 2, 2.5, 5, or 10 MHz input (0.3 to 4.0 Vpp into 50 Ω termination) Physical & Integration
Weight: 15 lbs; Dimensions: 20 × 18 × 12 inches
Rack-mountable (5.25 inches high)
VFD display
GPIB/IEEE-488 interface (standard)
Key Features
Dual time base options for varying stability requirements
Programmable output in 0.1 dB steps across full dynamic range
External reference frequency input for synchronization
Pulse modulator with nanosecond-class switching speed
Low spurious profile suitable for sensitive receiver testing
Typical Applications
Communication system transmitter/receiver verification
RF filter and amplifier characterization
Phase-locked loop and frequency synthesizer evaluation
Modulation quality assessment across AM, FM, and phase modes
Pulse-based system component testing
Compatibility & Integration Standard GPIB/IEEE-488 connectivity enables remote control and integration into automated test systems, simplifying multi-instrument coordination for production and development environments.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 100 kHz to 2.1 GHz | Power Range (dBm): '+16 dBm to −137 dBm (0.1 to 1050 MHz) |
| +13 dBm to −137 dBm (1050 to 2100 MHz) | Voltage / Current Range | 0.3 to 4.0 Vpp (external reference input) |
Fluke 6062A/AG — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Fluke 6062A/AG. Calibration covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common Fluke 6062A/AG faults: YIG oscillator failure (no output or loss of lock), step attenuator wear (output drops or steps at set attenuation), ALC loop failure (uncontrolled output power), I/Q modulator assembly failure. HP/Agilent 836xx series most common faults are YIG oscillator failure and step attenuator contact wear causing output steps or drops at specific attenuation settings. Keysight E4428C/E4438C units most commonly develop ALC loop failure and I/Q modulator assembly faults. YIG oscillator replacement and attenuator service are stocked repairs.
Fluke 6062A/AG price
This Fluke 6062A/AG is listed at $1,550. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Fluke 6062A/AG calibration cost
NIST-traceable calibration for the Fluke 6062A/AG is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. Turnaround is 1 to 3 business days after receipt. See full calibration details →