The Fluke 6062A/AG is a synthesized signal generator engineered for RF testing, communications systems evaluation, and component characterization. It delivers precise frequency synthesis across 100 kHz to 2.1 GHz with output levels spanning +16 dBm to −137 dBm, supported by multiple modulation modes and exceptional spectral purity. The instrument integrates GPIB/IEEE-488 control, making it suitable for both benchtop measurement and automated test environments.

Technical Specifications Frequency & Resolution

100 kHz to 2.1 GHz operating range

10 Hz frequency steps and resolution from 0.1 to 1050 MHz

20 Hz frequency steps and resolution from 1050 to 2100 MHz Output Power

+16 dBm to −137 dBm (0.1 to 1050 MHz)

+13 dBm to −137 dBm (1050 to 2100 MHz)

0.1 dB programmable steps with autoranging 6 dB step attenuator Amplitude Accuracy

±1.5 dB across specified operating ranges

±2.0 dB from +16 to −127 dBm (0.1 to 999.99999 MHz) Modulation

AM, FM, phase, and pulse modulation modes

AM depth: 0 to 99% in 1% increments

FM deviation: 1, 10, 100, and 400 kHz selectable

Phase deviation: 0.10, 1.0, 10.0, and 40.0 radians

Internal modulation oscillator: 400 to 1000 Hz selectable

Pulse modulation: 15 nanosecond rise and fall time (GaAs), ~50% internal duty cycle

External pulse: DC to 16 MHz rates, 0 to 100% duty cycle adjustable Spectral Purity

Non-harmonic spurious: <−60 dBc (0.1 to 1049.99999 MHz)

Non-harmonic spurious: 10 kHz offset)

Harmonics: <−30 dBc

Fixed frequency spurs: <−60 dBc or <−140 dBm (whichever larger) Time Base

Crystal time base with ±0.5 ppm/month ageing rate and ±5 ppm at 25°C

Optional medium-stability or ovenized high-stability time bases

External reference: 1, 2, 2.5, 5, or 10 MHz input (0.3 to 4.0 Vpp into 50 Ω termination) Physical & Integration

Weight: 15 lbs; Dimensions: 20 × 18 × 12 inches

Rack-mountable (5.25 inches high)

VFD display

GPIB/IEEE-488 interface (standard)

Key Features

Dual time base options for varying stability requirements

Programmable output in 0.1 dB steps across full dynamic range

External reference frequency input for synchronization

Pulse modulator with nanosecond-class switching speed

Low spurious profile suitable for sensitive receiver testing

Typical Applications

Communication system transmitter/receiver verification

RF filter and amplifier characterization

Phase-locked loop and frequency synthesizer evaluation

Modulation quality assessment across AM, FM, and phase modes

Pulse-based system component testing

Compatibility & Integration Standard GPIB/IEEE-488 connectivity enables remote control and integration into automated test systems, simplifying multi-instrument coordination for production and development environments.

Specifications

ParameterValue
Frequency Range100 kHz to 2.1 GHz | Power Range (dBm): '+16 dBm to −137 dBm (0.1 to 1050 MHz)
+13 dBm to −137 dBm (1050 to 2100 MHz) | Voltage / Current Range0.3 to 4.0 Vpp (external reference input)

Fluke 6062A/AG — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Fluke 6062A/AG. Calibration covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Fluke 6062A/AG faults: YIG oscillator failure (no output or loss of lock), step attenuator wear (output drops or steps at set attenuation), ALC loop failure (uncontrolled output power), I/Q modulator assembly failure. HP/Agilent 836xx series most common faults are YIG oscillator failure and step attenuator contact wear causing output steps or drops at specific attenuation settings. Keysight E4428C/E4438C units most commonly develop ALC loop failure and I/Q modulator assembly faults. YIG oscillator replacement and attenuator service are stocked repairs.

Fluke 6062A/AG price

This Fluke 6062A/AG is listed at $1,550. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Fluke 6062A/AG calibration cost

NIST-traceable calibration for the Fluke 6062A/AG is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. Turnaround is 1 to 3 business days after receipt. See full calibration details →