Anritsu 69053A Synthesized CW Generator, 10 MHz – 65 GHz
Anritsu 69053A,"Wideband CW generator supporting 10 MHz to 65 GHz for millimeter-wave and RF testing. Delivers stable, clean signals with low phase noise and fine frequency resolution. Ideal for advanced component testing, system integration, and automated test systems. Compatible with GPIB control and optimized for high-frequency reliability."
- Model
- Anritsu 69053A
- Calibration
- Available on request
- Price
- $35,670
- Status
- In stock
- RFQ ref
- 69053A
This unit
The Anritsu 69053A is a synthesized CW generator delivering stable, phase-coherent signals across 10 MHz to 65 GHz for RF and millimeter-wave testing. Single coaxial output with output power from -125 dBm to +17 dBm and ultra-low phase noise of -100 dBc/Hz at 10 kHz offset (referenced at 10 GHz) makes it suited for component characterization, system integration, and automated test environments. Frequency resolution of 1 kHz standard (0.1 Hz with Option 11) and 50 Ω output impedance ensure precision across its full range.
Technical Specifications
- Frequency Range: 10 MHz to 65 GHz (single coaxial output)
- Output Power: -125 dBm to +17 dBm maximum
- Phase Noise: -100 dBc/Hz SSB at 10 kHz offset from 10 GHz
- Frequency Resolution: 1 kHz standard; 0.1 Hz with Option 11
- Output Impedance: 50 Ω
- Harmonic Content: -40 dBc (harmonic and non-harmonic noise)
Key Features
- CW stimulus output with step sweep capability (1 to 10,000 steps)
- Step size configurable from 1 kHz to full frequency range; dwell time 1 ms to 99 seconds
- Frequency switching time less than 15 ms + 1 ms/GHz step size (typical maximum 40 ms)
- Alternate sweep mode between two ranges with independent power level assignment per range
- Manual sweep with phase-locked frequency tuning between limits
- Internal AM, FM, phase modulation, and pulse modulation; supports user-downloaded complex modulation
- Pulse modulation via internal generator or external control (doublet, triplet, quadruplet configurations)
- Simultaneous synchronized modulations for complex signal generation
- GPIB control interface with SCPI and native Anritsu command support
- Waveguide extensions available to 110 GHz
Typical Applications
- Component characterization and validation at millimeter-wave frequencies
- System integration and subsystem testing
- Automated test system stimulus source
- Phase noise and spectral purity validation
Compatibility & Integration GPIB control enables integration into automated test environments. Option 11 provides 0.1 Hz resolution for ultra-fine frequency tuning requirements.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 10 MHz to 65 GHz | Power Range (dBm): '-125 dBm to +17 dBm |
Anritsu 69053A — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Anritsu 69053A. Calibration covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common Anritsu 69053A faults: YIG oscillator failure (no output or loss of lock), step attenuator wear (output drops or steps at set attenuation), ALC loop failure (uncontrolled output power), I/Q modulator assembly failure. HP/Agilent 836xx series most common faults are YIG oscillator failure and step attenuator contact wear causing output steps or drops at specific attenuation settings. Keysight E4428C/E4438C units most commonly develop ALC loop failure and I/Q modulator assembly faults. YIG oscillator replacement and attenuator service are stocked repairs.
Anritsu 69053A price
This Anritsu 69053A is listed at $35,670. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Anritsu 69053A calibration cost
NIST-traceable calibration for the Anritsu 69053A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. Turnaround is 1 to 3 business days after receipt. See full calibration details →