Exfo FTB-5240S-P Optical Spectrum Analyzer Module
The EXFO FTB-5240S-P is an Optical Spectrum Analyzer (OSA) module designed for the FTB-200, FTB-500, and FTB-5240 platforms. It offers high-performance spectral analysis for various optical communication applications, including DWDM and CWDM system testing, spectral component analysis, and general-purpose optical measurements. This module provides accurate and reliable measurements of optical power, wavelength, and signal-to-noise ratio (OSNR), essential for ensuring the quality and performance of optical networks.
- Model
- Exfo FTB-5240S-P
- Calibration
- Available on request
- Price
- $8,170
- Status
- In stock
- RFQ ref
- FTB-5240S-P
This unit
The EXFO FTB-5240S-P Optical Spectrum Analyzer module delivers high-precision spectral analysis across the C- and L-bands for DWDM, CWDM, and advanced optical network deployments. This plug-in module integrates into FTB-2, FTB-2 Pro, FTB-400, FTB-500, and FTB-5240 platforms, enabling rapid commissioning, maintenance, and fault isolation in modern optical systems. The instrument provides simultaneous measurements of optical power, wavelength, and in-band OSNR with exceptional accuracy and dynamic range.
Technical Specifications Spectral Performance
Wavelength Range: 1250 nm to 1650 nm
Wavelength Uncertainty: ±0.05 nm typical; ±0.01 nm after user calibration (within 10 nm of calibration point)
Resolution Bandwidth: 0.065 nm (FWHM)
Wavelength Linearity: ±0.01 nm typical
Wavelength Repeatability: ±0.003 nm (2σ)
Optical Rejection Ratio: Up to 40 dBc at 0.2 nm (25 GHz) and 50 dBc at 0.4 nm (50 GHz); enhanced rejection with FTB-5240B option Power & Dynamic Range
Input Power Range: −70 dBm to +23 dBm per channel
Maximum Total Safe Power: +29 dBm
Dynamic Range: 93 dB typical (exceeds 90 dB per scan)
Absolute Power Uncertainty: ±0.5 dB
Power Repeatability: ±0.05 dB (2σ) OSNR Measurement
In-band OSNR analysis via PROS-OSNR method
Accurate measurement in systems with fluctuating noise floors
Optimized for 40 Gbit/s and ROADM architectures
Key Features
Dedicated measurement modes: DWDM, CWDM, EDFA, signal drift, spectral transmittance, DFB laser analysis
Internal wavelength reference with optional user calibration
Dual connector support: EI (UPC) and EA (APC) EXFO universal interfaces
Operating temperature range: 0 °C to 40 °C
Compact form factor: 96 mm H × 51 mm W × 260 mm D (1.5 kg)
Typical Applications
DWDM system characterization and monitoring
CWDM channel verification
EDFA gain and noise figure analysis
Wavelength drift detection
Component spectral transmittance measurement
DFB laser spectral purity assessment
Specifications
| Parameter | Value |
|---|---|
| Power Range (dBm) | −70 dBm to +23 dBm | Wavelength Range: 1250 nm to 1650 nm |
Frequently Asked Questions
- What does the Exfo FTB-5240S-P measure and what are its key specifications?
- The FTB-5240S-P is an Optical Spectrum Analyzer module that measures optical power across the C-band and L-band wavelength range from 1250 nm to 1650 nm, with a dynamic power range of −70 dBm to +23 dBm. This module is engineered for high-resolution spectral analysis in DWDM and CWDM system testing, spectral component characterization, and general optical communication measurements. It integrates seamlessly into EXFO's modular FTB platforms—the FTB-200, FTB-500, and FTB-5240—making it suitable for both field deployment and laboratory environments.
- What is the condition of this used Exfo FTB-5240S-P, and what has been verified?
- This unit is sold in used condition and has been functionally inspected to confirm operational status. We verify core measurement functionality and mechanical integrity before listing, ensuring the module powers on and responds to control commands within the stated performance envelope. As with all used test equipment, cosmetic wear may be present, but the optical and electronic components meet working standards for immediate deployment.
- Is calibration available for the FTB-5240S-P, and what does it cost?
- Yes, NIST-traceable calibration is available as a separately ordered service starting at $450, which covers the optical power measurement path and wavelength reference accuracy. Calibration certification documents the module's conformance to published specifications and is recommended for quality assurance and regulated applications. Lead time and detailed scope of calibration work can be provided upon request through our service team.
- What interfaces and connectivity options does the FTB-5240S-P support?
- The FTB-5240S-P connects to its host FTB platform via a proprietary module slot interface and inherits the platform's control connectivity—typically GPIB, USB, and Ethernet, depending on the chassis model. Software control is managed through EXFO's instrument drivers and platform software suite, which support remote automation and data logging for system integration. Consult the host platform's documentation for specific interface availability and driver compatibility with your operating environment.
Exfo FTB-5240S-P — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Exfo FTB-5240S-P. Calibration covers wavelength accuracy at 850, 1310, 1550, and 1625 nm, power level accuracy, resolution bandwidth (RBW) accuracy, and dynamic range verification. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common Exfo FTB-5240S-P faults: wavelength motor failure, internal light source dimming, detector sensitivity loss. Common repairs include wavelength motor servicing, internal broadband source replacement, and detector recalibration after extended use.
Exfo FTB-5240S-P price
This Exfo FTB-5240S-P is listed at $8,170. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Exfo FTB-5240S-P calibration cost
NIST-traceable calibration for the Exfo FTB-5240S-P is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers wavelength accuracy at 850, 1310, 1550, and 1625 nm, power level accuracy, resolution bandwidth (RBW) accuracy, and dynamic range verification. Turnaround is 1 to 3 business days after receipt. See full calibration details →