Fluke 742A-100 Resistance Standard

Fluke Calibration Equipment. Current: 20 mA, Voltage: 2 V.

Model
Fluke 742A-100
Calibration
Available on request
Price
$165
Status
In stock
RFQ ref
742A-100
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Fluke 742A-100 is a precision 100 Ω resistance standard engineered for calibration and verification of resistance measuring instruments in metrology labs and production environments. Built from hermetically-sealed wirewound resistor arrays with no adjustable components, it delivers calibration uncertainty of ± 1.0 ppm at 23°C and six-month stability of ≤ 2.5 ppm. The unit requires no temperature-controlled air or oil baths and arrives with NIST-traceable calibration documentation including temperature characterization data in 0.5°C increments.


Technical Specifications

Resistance & Accuracy

  • Nominal resistance: 100 Ω

  • Initial trim: ± 2 ppm of nominal

  • Calibration uncertainty (23°C): ± 1.0 ppm

  • Six-month stability: ≤ 2.5 ppm

  • One-year stability: ≤ 4 ppm Temperature Performance

  • Operating range: 18°C to 28°C

  • Storage range: 0°C to 40°C

  • Temperature coefficient: Near zero at 23°C

  • Maximum deviation (18°C to 28°C): ≤ 3.0 ppm

  • Retrace error (0°C to 40°C cycles): Typically < 2 ppm Electrical Ratings

  • Maximum current: 20 mA

  • Maximum voltage: 2 V Connectors

  • Five-way tellurium-copper binding posts (current HI/LO, sense HI/LO, chassis ground)

  • Low-thermal emf construction Physical

  • Dimensions: 8.6 cm H × 10.5 cm W × 12.7 cm D

  • Weight: 0.68 kg to 0.91 kg


Key Features



  • No oil or air bath required

  • Hermetically-sealed construction minimizes thermal and mechanical shock effects

  • Temperature characterization table in 0.5°C increments supplied with calibration report

  • Four-terminal configuration supports precision kelvin resistance measurement

  • NIST-traceable calibration from Fluke Primary Standards Lab


Typical Applications



  • Resistance meter and multimeter calibration

  • Data acquisition system validation

  • Production test equipment traceability

  • Metrology laboratory reference standards

  • Temperature-corrected measurement verification


Compatibility & Integration Connects directly to four-terminal resistance measurement systems via standard binding posts. Temperature correction data provided on calibration certificate enables operation across 18°C to 28°C with minimal uncertainty.

Specifications

ParameterValue
Voltage / Current Range0-2 V, 0-20 mA

Fluke 742A-100 — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Fluke 742A-100. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Fluke 742A-100 price

This Fluke 742A-100 is listed at $165. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Fluke 742A-100 calibration cost

NIST-traceable calibration for the Fluke 742A-100 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents