Fluke 742A-100 Resistance Standard
Fluke Calibration Equipment. Current: 20 mA, Voltage: 2 V.
- Model
- Fluke 742A-100
- Calibration
- Available on request
- Price
- $165
- Status
- In stock
- RFQ ref
- 742A-100
This unit
The Fluke 742A-100 is a precision 100 Ω resistance standard engineered for calibration and verification of resistance measuring instruments in metrology labs and production environments. Built from hermetically-sealed wirewound resistor arrays with no adjustable components, it delivers calibration uncertainty of ± 1.0 ppm at 23°C and six-month stability of ≤ 2.5 ppm. The unit requires no temperature-controlled air or oil baths and arrives with NIST-traceable calibration documentation including temperature characterization data in 0.5°C increments.
Technical Specifications
Resistance & Accuracy- Nominal resistance: 100 Ω
- Initial trim: ± 2 ppm of nominal
- Calibration uncertainty (23°C): ± 1.0 ppm
- Six-month stability: ≤ 2.5 ppm
- One-year stability: ≤ 4 ppm Temperature Performance
- Operating range: 18°C to 28°C
- Storage range: 0°C to 40°C
- Temperature coefficient: Near zero at 23°C
- Maximum deviation (18°C to 28°C): ≤ 3.0 ppm
- Retrace error (0°C to 40°C cycles): Typically < 2 ppm Electrical Ratings
- Maximum current: 20 mA
- Maximum voltage: 2 V Connectors
- Five-way tellurium-copper binding posts (current HI/LO, sense HI/LO, chassis ground)
- Low-thermal emf construction Physical
- Dimensions: 8.6 cm H × 10.5 cm W × 12.7 cm D
- Weight: 0.68 kg to 0.91 kg
Key Features
- No oil or air bath required
- Hermetically-sealed construction minimizes thermal and mechanical shock effects
- Temperature characterization table in 0.5°C increments supplied with calibration report
- Four-terminal configuration supports precision kelvin resistance measurement
- NIST-traceable calibration from Fluke Primary Standards Lab
Typical Applications
- Resistance meter and multimeter calibration
- Data acquisition system validation
- Production test equipment traceability
- Metrology laboratory reference standards
- Temperature-corrected measurement verification
Compatibility & Integration Connects directly to four-terminal resistance measurement systems via standard binding posts. Temperature correction data provided on calibration certificate enables operation across 18°C to 28°C with minimal uncertainty.
Specifications
| Parameter | Value |
|---|---|
| Voltage / Current Range | 0-2 V, 0-20 mA |
Fluke 742A-100 — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Fluke 742A-100. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.
Fluke 742A-100 price
This Fluke 742A-100 is listed at $165. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Fluke 742A-100 calibration cost
NIST-traceable calibration for the Fluke 742A-100 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →