Fluke 792A – AC/DC Transfer Standard with 792A Power Pack

The Fluke 792A AC/DC Transfer Standard is a precision instrument used for transferring AC voltage and current measurements to DC standards, ensuring high accuracy in calibration and metrology applications. Includes 792A Power Pack.

Model
Fluke 792A
Calibration
Available on request
Price
$12,500
Status
In stock
RFQ ref
792A
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Fluke 792A AC/DC Transfer Standard with 792A Power Pack is a precision thermal transfer instrument engineered for ultra-high-accuracy AC/DC voltage and current measurements in primary calibration laboratories. It establishes traceability between AC measurements and DC standards using a patented Solid-State Thermal RMS sensor and thin-film range resistors, achieving total uncertainties as low as ±10 ppm (±5 ppm optional from Fluke's Primary Standards Lab) traceable to NIST.

Technical Specifications Measurement Range & Accuracy

Voltage: 2 mV to 1000 V (with external 1000 V range resistor); internal ranges to 220 V

Frequency: 10 Hz to 1 MHz

Volt-Hertz product maximum: 10 × 10⁶ V·Hz

Total uncertainty: ±10 ppm (standard), ±5 ppm (optional primary lab grade)

AC/DC reversal error: as low as 10 ppm relative to input voltage Thermal RMS Sensor The patented Solid-State Thermal Voltage Converter (TVC) delivers 2 V nominal full-scale output with excellent signal-to-noise characteristics and minimal thermal mass. Stabilization occurs in approximately 30 seconds; system warm-up requires 15 minutes after 12-hour environmental stabilization. Range Resistors Thin-film construction with low temperature coefficient, rapid stabilization, and minimal AC/DC differences. The 1000 V range resistor is isolated externally to eliminate heat generation at elevated voltages.

Key Features

Output: 2 V full-scale DC, compatible with high-resolution digital multimeters

Input connector: Stainless Steel Type-N (rear panel)

Output binding posts: HI, LO, GUARD, GROUND (front panel)

Overload protection: Visual and audible alerts; electronically protected

Current limitation requirement: sources must be current-limited to 200 mA maximum

NIST traceability with correction factor tables and uncertainty documentation

Typical Applications

Primary AC voltage and current calibration

AC/DC transfer standard operations in national metrology institutes

Multi-frequency AC measurement verification (10 Hz to 1 MHz)

High-accuracy voltage reference establishment across broad measurement ranges

Compatibility & Integration The 792A Power Pack supplies the instrument. Type-N input connectors enable integration with precision signal sources. Output via binding posts allows direct connection to precision digital multimeters or data acquisition systems.

Specifications

ParameterValue
Frequency Range10 Hz to 1 MHz | Voltage / Current Range: 2 mV to 1000 V

Fluke 792A — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Fluke 792A. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Fluke 792A price

This Fluke 792A is listed at $12,500. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Fluke 792A calibration cost

NIST-traceable calibration for the Fluke 792A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →