HP / Agilent 83732A Synthesized signal generator, 0.01-20GHz
The HP/Agilent 83732A is a synthesized signal generator that operates from 0.01 GHz to 20 GHz. It provides high-performance signal generation with wide frequency coverage and precise control over output parameters. Ideal for testing and characterizing RF and microwave components and systems.
- Model
- HP / Agilent 83732A
- Calibration
- Available on request
- Price
- $11,158
- Status
- In stock
- RFQ ref
- 83732A
This unit
The HP/Agilent 83732A is a synthesized signal generator engineered for RF and microwave test applications spanning 0.01 GHz to 20 GHz. This instrument delivers precise signal generation with excellent spectral purity, adjustable output power, and versatile modulation modes including FM, pulse, and logarithmic AM. It serves radar, electronic warfare, and telecommunications characterization with 1 kHz frequency resolution (1 Hz optional) and 0.01 dB power resolution across its operating range.
Technical Specifications Frequency & Resolution
Range: 0.01 GHz to 20 GHz
Resolution: 1 kHz standard; 1 Hz with Option 1E8
External reference: 10 MHz Output Power
0.01–1 GHz: +13 dBm typical maximum
1–20 GHz: +11 to +13 dBm typical maximum
Impedance: 50 Ω
Power resolution: 0.01 dB
Output accuracy: ±1.0 dB (typical); ±2.3 dB (overall)
Level switching time: <15 ms (without step attenuator change) Spectral Performance
Harmonics: <−55 dBc
Non-harmonic spurious: 3 kHz offset)
Phase noise @ 10 kHz offset: −103 dBc/Hz (500 MHz), −91 dBc/Hz (2 GHz), −73 dBc/Hz (18 GHz)
Broadband noise floor: 80 dB; rise/fall times <10 ns; minimum width 3 MHz; width 25 ns to 419 ms; delay ±419 ms (free-run)
FM rate: 1 kHz to 1 MHz; maximum deviation 10 MHz pk (2–20 GHz), 5 MHz pk (1–2 GHz)
Log AM depth: >60 dB
Key Features
User level correction for accurate power at distant test ports
Internal multimode pulse generator: triggered, doublet, and gated burst operation
Sub-harmonics eliminated
Broadband noise minimized for low-gain device measurements
Typical Applications
Radar system testing and characterization
Electronic warfare signal simulation
Telecommunications equipment validation
Component and subsystem RF performance assessment
Compatibility & Integration
50 Ω output impedance matches standard test setups
10 MHz external frequency reference input for synchronization
Optional 1E5 high-stability timebase for phase noise offsets <100 Hz
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 0.01 GHz to 20 GHz | Power Range (dBm): '+11 to +13 dBm (1–20 GHz), +13 dBm (0.01–1 GHz) |
HP / Agilent 83732A — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the HP / Agilent 83732A. Calibration covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common HP / Agilent 83732A faults: YIG oscillator failure (no output or loss of lock), step attenuator wear (output drops or steps at set attenuation), ALC loop failure (uncontrolled output power), I/Q modulator assembly failure. HP/Agilent 836xx series most common faults are YIG oscillator failure and step attenuator contact wear causing output steps or drops at specific attenuation settings. Keysight E4428C/E4438C units most commonly develop ALC loop failure and I/Q modulator assembly faults. YIG oscillator replacement and attenuator service are stocked repairs.
HP / Agilent 83732A price
This HP / Agilent 83732A is listed at $11,158. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
HP / Agilent 83732A calibration cost
NIST-traceable calibration for the HP / Agilent 83732A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. Turnaround is 1 to 3 business days after receipt. See full calibration details →