Fluke 845AR
Fluke Laboratory Measurement Instruments. Model: 845AR.
- Model
- Fluke 845AR
- Calibration
- Available on request
- Price
- $1,050
- Status
- In stock
- RFQ ref
- 845AR
This unit
The Fluke 845AR is a high-impedance DC voltmeter and null detector engineered for precision measurement applications requiring exceptional input impedance, sensitivity, and isolation. This solid-state instrument delivers accurate DC voltage measurements across 19 ranges from 1 µV to 1000 V, making it essential for laboratory, test, and calibration work where source loading must be minimized and measurement fidelity is non-negotiable.
Technical Specifications Measurement Ranges: 19 ranges, 1 µV to 1000 V DC with X1 and X3 progression. Input Resistance: Better than 10¹⁰ Ω at 80% RH and 35°C; improves to better than 10¹³ Ω with driven guard. Range-dependent impedance: 100 MΩ (300 mV and above), 10 MΩ (3 mV to 100 mV), 1 MΩ (1 mV and below). Null detector mode on ranges 100 mV and below: 10 MΩ input impedance. Input Voltage Isolation: Input floatable to 1100 V above ground. Leakage isolation: better than 10¹² Ω regardless of power, chassis ground, or guard connections; better than 10¹² Ω at less than 50% RH and 25°C. Overload Protection: 1100 V on all ranges with approximately 4 second recovery time. Accuracy: ±(3% of end scale + 0.1 µV) for Fluke 845AR; ±(2% of end scale + 0.1 µV) for Fluke 845AB. Common Mode Rejection (DC): Better than 160 dB (short-circuited, 80% RH); better than 140 dB (open, 50% RH); better than 120 dB (open, 80% RH). Derates 20 dB across 0–50°C. AC rejection (below 100 kHz): 100 Vrms or 120 dB greater than end scale (whichever is less) with less than 2% end scale error. Normal Mode Rejection (AC, 60 Hz and above): AC voltages 60 dB above end scale with less than 2% end scale error. Maximum 750 Vrms. Zero Stability: Better than 0.15 µV/hour and 0.3 µV/day. Temperature coefficient: less than 0.1 µV/°C (15–35°C); less than 0.2 µV/°C (0–50°C). Zero control range: ±5 µV minimum. Recorder Output: 0–1 V DC, linear to 0.5% end scale. Isolated from input. Maximum gain: 120 dB. Source impedance: 5 kΩ to 7.5 kΩ. Power: 115/230 VAC ±10%, 50–440 Hz, approximately 3 W.
Key Features
Extreme input isolation eliminates source loading effects
Isolated recorder output enables direct integration with data acquisition systems
Driven guard option elevates input impedance to 10¹³ Ω
Overload protection to 1100 V
Sub-microvolt zero stability and drift
Typical Applications
Thermocouple and sensor bridge measurement
Potentiometer calibration and comparison
Null detection in precision test circuits
Low-level DC signal acquisition in shielded environments
Compatibility & Integration Standard EIA 19-inch relay rack mount with resilient benchtop feet. Isolated 0–1 V DC recorder output for chart recorders, data loggers, and instrumentation interfaces.
Specifications
| Parameter | Value |
|---|---|
| Voltage / Current Range | 1 µV to 1000 V DC |
Fluke 845AR — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Fluke 845AR. Calibration covers calibration scope varies by instrument type: vacuum gauges are verified at multiple pressure points against NIST-traceable pressure standards; spectrophotometers at wavelength accuracy and photometric accuracy points; strain gauge indicators at bridge excitation accuracy and full-scale output accuracy; pH meters against certified buffer solutions at pH 4, 7, and 10.. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common Fluke 845AR faults: vacuum gauge filament failure (ionization gauges), spectrophotometer D2 lamp end-of-life, wavelength motor failure, strain indicator front-panel binding post corrosion, pH electrode conditioning failure. Most specialty laboratory instruments fail at their electromechanical interfaces first — vacuum gauge connectors and filament assemblies, spectrophotometer lamp housings and motor drives, strain indicator binding post corrosion. Component-level repair is standard; manufacturer support for legacy instruments is often limited, making third-party bench repair the practical path.
Fluke 845AR price
This Fluke 845AR is listed at $1,050. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Fluke 845AR calibration cost
NIST-traceable calibration for the Fluke 845AR is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers calibration scope varies by instrument type: vacuum gauges are verified at multiple pressure points against NIST-traceable pressure standards; spectrophotometers at wavelength accuracy and photometric accuracy points; strain gauge indicators at bridge excitation accuracy and full-scale output accuracy; pH meters against certified buffer solutions at pH 4, 7, and 10.. Turnaround is 1 to 3 business days after receipt. See full calibration details →