Agilent / Keysight 86111A 3 GHz dual channel amplified optical module 750-860 nm
The Agilent/Keysight 86111A is a 3 GHz dual-channel amplified optical module designed for use in optical test and measurement systems. It operates in the 750-860 nm wavelength range and provides amplification for optical signals. This module is ideal for analyzing and characterizing optical components and systems.
- Model
- Agilent / Keysight 86111A
- Calibration
- Available on request
- Price
- $20,878
- Status
- In stock
- RFQ ref
- 86111A
This unit
The Agilent/Keysight 86111A is a dual-channel amplified optical module for high-speed optical signal characterization in the 750–860 nm wavelength band. Operating at 3 GHz bandwidth, it enables simultaneous measurements across multiple optical channels, eliminating sequential testing requirements and improving measurement throughput for parallel optic component validation.
Technical Specifications
- Bandwidth: 3 GHz
- Wavelength Range: 750–860 nm
- Channels: Dual optical channels
- Switchable Filters: 2 filters
- Filtered Data Rates: 155 Mb/s, 622 Mb/s
Key Features
- Dual-channel architecture supports concurrent measurement of multiple optical paths, reducing test cycle time for network equipment and optical component development.
- Two switchable filters provide selection between 155 Mb/s and 622 Mb/s filtered data rates for signal conditioning across common optical network speeds.
- Amplified photodetection delivers direct optical-to-electrical conversion with gain optimization for weak-signal applications.
Typical Applications
- Optical network interface testing and characterization
- Multi-channel parallel optical component validation
- High-speed optical signal analysis for transceiver and module development
- Optical receiver sensitivity and eye-diagram measurements
Compatibility & Integration The 86111A integrates directly into Agilent DCA Mainframes of the 86100x Series, including the 86100A/B, 86100C, and 86100D Infiniium DCA platforms. Module insertion into a compatible mainframe provides measurement control, data acquisition, and analysis within the DCA software environment.
Specifications
| Parameter | Value |
|---|---|
| Wavelength Range | 750–860 nm |
Agilent / Keysight 86111A — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Agilent / Keysight 86111A. Calibration covers gain at rated input power across the specified wavelength range, noise figure at rated gain setting, output power accuracy, gain flatness across the C-band or specified wavelength range, and polarization-dependent gain (PDG) where applicable. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common Agilent / Keysight 86111A faults: pump laser diode degradation (gain drop, reduced output power), TEC failure causing thermal drift, optical isolator degradation, power supply failure. The most common failure on any EDFA is pump laser diode degradation. Secondary faults include TEC failure causing thermal runaway, optical isolator degradation, and power supply failure.
Agilent / Keysight 86111A price
This Agilent / Keysight 86111A is listed at $20,878. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Agilent / Keysight 86111A calibration cost
NIST-traceable calibration for the Agilent / Keysight 86111A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers gain at rated input power across the specified wavelength range, noise figure at rated gain setting, output power accuracy, gain flatness across the C-band or specified wavelength range, and polarization-dependent gain (PDG) where applicable. Turnaround is 1 to 3 business days after receipt. See full calibration details →