This unit
The JDS Uniphase OAB1552+1FP0 is an Erbium-Doped Fiber Amplifier (EDFA) module engineered for telecommunications and data center applications across the C-band. Operating in the 1528–1565 nm wavelength range, this unit boosts optical signal power to extend transmission distances and enhance network performance. It supports deployment as a pre-amplifier, booster, or in-line amplifier in single-channel and multichannel (DWDM) systems. The compact benchtop form factor integrates easily into both laboratory and rack-mountable environments.
Technical Specifications
Amplifier Type: Erbium-Doped Fiber Amplifier (EDFA)
Operating Wavelength Range: 1528–1565 nm (C-band)
Saturated Output Power: 17 dBm minimum (booster configuration)
Noise Figure: 4.5 dB maximum (booster configuration)
Small Signal Gain: 20–24 dB minimum (booster configuration); 37 dB (pre-amplifier configuration)
Amplifier Configurations: Pre-amplifier, booster, in-line amplifier
Key Features
Optical connectors: FC/PC, FC/APC, SC/PC, or SC/APC
LCD display for real-time monitoring of input/output power and current
RS232 remote control interface
Compact dimensions: 21.2 × 8.9 × 35.5 cm (W × H × D)
Weight: Less than 4 kg
Operating temperature: 0–50 °C; storage: −40–70 °C
Maximum humidity: 95% RH non-condensing (0–45 °C)
Laser safety: FDA 21 CFR 1040.10 Class IIIb compliant (maximum output ≤24.5 dBm)
Certifications: CE, cULus; standards compliance with UL3101-1 and CAN/CSA-C22.2 No. 1010.1
Typical Applications
Pre-amplifier configurations for weak signal recovery
Booster amplifier stages for power elevation
In-line amplifier deployment in long-haul and metropolitan networks
Single-channel and DWDM system integration
Compatibility & Integration The OAB1552+1FP0 accepts single-channel and multichannel (DWDM) optical inputs across the C-band. Standard fiber connectors ensure compatibility with existing telecommunications infrastructure. The integrated LCD and RS232 control enable straightforward laboratory and field deployment.
Specifications
| Parameter | Value |
|---|---|
| Power Range (dBm) | 17 dBm minimum output (booster) |
| ≤24.5 dBm maximum output | Wavelength Range | 1528–1565 nm |
JDS Uniphase OAB1552+1FP0 — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the JDS Uniphase OAB1552+1FP0. Calibration covers gain at rated input power across the specified wavelength range, noise figure at rated gain setting, output power accuracy, gain flatness across the C-band or specified wavelength range, and polarization-dependent gain (PDG) where applicable. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common JDS Uniphase OAB1552+1FP0 faults: pump laser diode degradation (gain drop, reduced output power), TEC failure causing thermal drift, optical isolator degradation, power supply failure. The most common failure on any EDFA is pump laser diode degradation. Secondary faults include TEC failure causing thermal runaway, optical isolator degradation, and power supply failure.
JDS Uniphase OAB1552+1FP0 price
This JDS Uniphase OAB1552+1FP0 is listed at $4,600. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
JDS Uniphase OAB1552+1FP0 calibration cost
NIST-traceable calibration for the JDS Uniphase OAB1552+1FP0 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers gain at rated input power across the specified wavelength range, noise figure at rated gain setting, output power accuracy, gain flatness across the C-band or specified wavelength range, and polarization-dependent gain (PDG) where applicable. Turnaround is 1 to 3 business days after receipt. See full calibration details →