Agilent / Keysight 86143A Portable Standard Performance Optical Spectrum Analyzer
The Keysight 86143A is a portable optical spectrum analyzer (OSA) for field and lab use. It covers 600–1700 nm with high resolution (0.07 nm), ideal for DWDM, laser, and amplifier testing. Its compact design and battery operation enable flexible deployment in various optical network environments.
- Model
- Agilent / Keysight 86143A
- Calibration
- Available on request
- Price
- $10,834
- Status
- In stock
- RFQ ref
- 86143A
This unit
The Agilent/Keysight 86143A is a portable optical spectrum analyzer engineered for field and laboratory deployment across optical networks. It delivers precise characterization of optical signals from 600 nm to 1700 nm, making it well-suited for DWDM system analysis, laser diode testing, and optical amplifier characterization. Battery-powered operation and compact form factor enable rapid troubleshooting in central offices and remote field locations without sacrificing measurement accuracy.
Technical Specifications
Wavelength Performance:- Range: 600 nm to 1700 nm
- Span: 0.2 nm to full range, continuously variable (zero span capable)
- Wavelength accuracy (after internal calibration, 1510–1570 nm): ±0.025 nm
- Wavelength accuracy (after internal calibration, 1570–1640 nm): ±0.035 nm
- Wavelength accuracy (user calibration within ±40 nm): ±0.05 nm
- Wavelength accuracy (user calibration, full range): ±0.2 nm
- Absolute accuracy (2-year factory cycle): ±0.5 nm
- Reproducibility (≤1 minute): ±0.003 nm
- Tuning repeatability: ±0.003 nm Resolution Bandwidth:
- Selectable FWHM: 0.07 nm, 0.1 nm, 0.2 nm, 0.5 nm, 1 nm, 2 nm, 5 nm, 10 nm Power Measurement:
- Input power range: -90 dBm to -60 dBm
- Maximum dynamic range: -52 dB
- Measurement accuracy: ±0.1 dB
- Power accuracy at -20 dBm (1550 nm, 20–30 °C): ±0.35 dB
- Maximum safe input: +20 dBm
- Scale fidelity (fixed reference): ±0.05 dB (characteristic)
- Scale fidelity (variable reference): ±0.07 dB (characteristic)
- Sensitivity: Signal > 6× RMS noise Sweep Performance:
- Minimum sweep time: 180 ms
- Maximum sweep time: 650 ms
- 50 nm span (auto zero off): <180 ms
- 100 nm span: <400 ms
- 500 nm span: <650 ms Polarization Dependence (characteristic):
- At ±0.8 nm (±100 GHz @ 1550 nm): -60 dB
- At ±0.5 nm (±62.5 GHz @ 1550 nm): -58 dB
- At ±0.4 nm (±50 GHz @ 1550 nm): -55 dB
- At ±0.2 nm (±25 GHz @ 1550 nm): -40 dB
Key Features
- Portable form factor with battery operation for field deployment
- Wide spectral coverage (600–1700 nm) from UV to near-infrared
- Sub-picometer wavelength reproducibility and tuning stability
- Eight selectable resolution bandwidths for flexible signal analysis
- Rapid sweep capability (180–650 ms) for real-time monitoring
Typical Applications
- DWDM channel isolation and characterization
- Laser diode spectral analysis
- Optical amplifier gain profiling
- Fiber optic network commissioning and troubleshooting
- Signal quality verification across telecommunications bands
Specifications
| Parameter | Value |
|---|---|
| Power Range (dBm) | '-90 dBm to -60 dBm (input) |
| +20 dBm maximum safe input power | Voltage / Current Range | 44–444 Hz, 90–260 VAC | Wavelength Range: 600 nm to 1700 nm |