Fluke 87V-NIST True RMS Industrial Multimeter with temperature

The Fluke 87V-NIST True RMS Industrial Multimeter with temperature is a versatile tool for troubleshooting and diagnostics in industrial settings. It accurately measures AC and DC voltage, current, resistance, frequency, and temperature. The multimeter features a large, backlit display for easy reading in any environment, and its rugged design ensures reliable performance even in harsh conditions. Includes NIST-traceable calibration certificate.

Model
Fluke 87V-NIST
Calibration
Available on request
Price
$470
Status
In stock
RFQ ref
87V-NIST
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Fluke 87V-NIST is a True RMS industrial multimeter engineered for electrical diagnostics in demanding environments. It measures DC/AC voltage to 1000 V, DC/AC current to 10 A (20 A/30 sec), resistance to 50 MΩ, capacitance to 9999 µF, frequency to 200 kHz, and temperature to 1090°C. A NIST-traceable calibration certificate and full uncertainty data ship with every unit.

Technical Specifications Voltage Measurement

DC: 1000 V max, ±(0.05% + 1) accuracy, 10 µV resolution

AC True RMS: 1000 V max, ±(0.7% + 2) accuracy, 0.1 mV resolution, 20 kHz bandwidth with low-pass filter Current Measurement

DC: 10 A max (20 A/30 sec), ±(0.2% + 2) accuracy, 0.01 µA resolution

AC True RMS: 10 A max (20 A/30 sec), ±(1.0% + 2) accuracy, 0.1 µA resolution Resistance, Capacitance, Frequency

Resistance: 50 MΩ max, ±(0.2% + 1) accuracy, 0.1 Ω resolution

Capacitance: 9999 µF max, ±(1% + 2) accuracy, 0.01 nF resolution

Frequency: 200 kHz max, ±(0.005% + 1) accuracy, 0.01 Hz resolution Temperature

Display range: -200 to 1090°C (-328 to 1994°F)

With 80 BK probe: -40 to 260°C (-40 to 500°F)

Accuracy: 1.0% Physical & Safety

Display: 6000 counts (3-3/4 digit) or 20,000 counts (4-1/2 digit) with two-level backlight

Safety: CAT III 1000 V / CAT IV 600 V

Impulse withstand: >8000 V

Operating temp: -20 to 55°C

Dimensions: 201 × 98 × 52 mm; Weight: 355 g

Key Features

Adjustable speed motor drive function with low-pass filter for noise rejection on electrically noisy equipment

Peak Min/Max capture detects glitches and spikes as short as 250 µs

NIST-traceable calibration with full data and uncertainties

Typical Applications Motor drives, plant automation, power distribution, and electromechanical equipment troubleshooting.

Specifications

ParameterValue
Frequency RangeDC to 200 kHz | Voltage / Current Range: 0-10 A DC/AC (20 A/30 sec), 0-1000 V DC/AC

Fluke 87V-NIST — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Fluke 87V-NIST. Calibration covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Fluke 87V-NIST faults: blown input fuse, worn input jacks, display segment failure, relay contact wear on bench DMMs. Common faults include worn input jacks (banana socket contact wear on the mA and COM terminals), blown input fuses (especially the 440 mA HRC fuse), and display segment failures. Keithley 2000/2001/2002 bench DMMs commonly develop relay contact wear affecting resistance accuracy after extended service.

Fluke 87V-NIST price

This Fluke 87V-NIST is listed at $470. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Fluke 87V-NIST calibration cost

NIST-traceable calibration for the Fluke 87V-NIST is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents