Fluke 8845A 6.5 Digit Precision Multimeter
Fluke Laboratory Measurement Instruments. Accuracy: 0.0024% (1 year), Resolution: 100 pA, Resolution: 10 µΩ.
- Model
- Fluke 8845A
- Calibration
- Available on request
- Price
- $1,100
- Status
- In stock
- RFQ ref
- 8845A
This unit
The Fluke 8845A is a 6.5-digit precision multimeter engineered for calibration, research, and development environments requiring high-accuracy electrical measurements. It delivers DC voltage accuracy to 0.0024% over one year and measures voltage, current, resistance, frequency, and period across wide dynamic ranges. The instrument combines benchtop usability with systems integration capability, featuring dual-display simultaneous measurement, graphical analysis modes, and multiple connectivity options for seamless integration into automated test systems.
Technical Specifications Measurement Resolution & Accuracy
6.5-digit resolution
DC voltage accuracy: 0.0024% (1 year)
VFD dot matrix display DC Current
Range: 100 µA to 10 A
Resolution: 100 pA Resistance
Range: 10 Ω to 1 GΩ
Resolution: 10 µΩ
Patented 2×4 ohms 4-wire measurement with split terminal jacks enables precision 4-wire resistance measurements using two leads AC Voltage, AC Current, Frequency, and Period
Full measurement capability included Physical
Dimensions: 88 mm H × 217 mm W × 297 mm D
Weight: 3.6 kg
Key Features
Dual-display mode measures two parameters simultaneously from a single test connection
Trendplot™ paperless recorder identifies signal quality issues, drift, and intermittents
Histogram analysis reveals stability and noise problems in analog circuits
Real-time trend plot and histogram viewing via Analyze mode
CAT I 1000 V and CAT II 600 V safety rating per IEC 61010-1 2000-1 and ANSI/ISA-S82.01-1994
Interfaces & Integration Serial, IEEE-488, and Ethernet connectivity support system automation. Native emulation of Fluke 45 and Agilent 34401A instruments simplifies integration into existing test architectures. FlukeView® Forms Basic documentation software is included for measurement logging and analysis.
Typical Applications Calibration laboratories, product development, manufacturing test, and research settings where precision DC measurements and graphical signal analysis are critical.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | Frequency and period measurement capability included | Voltage / Current Range: DC Current: 100 µA to 10 A |
| Resistance | 10 Ω to 1 GΩ |
Fluke 8845A — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Fluke 8845A. Calibration covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common Fluke 8845A faults: blown input fuse, worn input jacks, display segment failure, relay contact wear on bench DMMs. Common faults include worn input jacks (banana socket contact wear on the mA and COM terminals), blown input fuses (especially the 440 mA HRC fuse), and display segment failures. Keithley 2000/2001/2002 bench DMMs commonly develop relay contact wear affecting resistance accuracy after extended service.
Fluke 8845A price
This Fluke 8845A is listed at $1,100. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Fluke 8845A calibration cost
NIST-traceable calibration for the Fluke 8845A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. Turnaround is 1 to 3 business days after receipt. See full calibration details →