Agilent/Keysight U3401A

The Agilent/Keysight U3401A is a 4.5-digit digital multimeter offering a broad range of measurement functions including DC/AC voltage and current, resistance, frequency, capacitance, and temperature. It features a bright LCD display, USB connectivity for data logging, and built-in math functions for advanced analysis. Ideal for electronics testing, troubleshooting, and education.

Model
Agilent / Keysight U3401A
Calibration
Available on request
Price
$450
Status
In stock
RFQ ref
U3401A
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Agilent/Keysight U3401A is a 4.5-digit dual-display digital multimeter delivering 11 measurement functions and 6 built-in math operations for electronics testing, troubleshooting, and educational applications. The instrument features a bright VFD display enabling simultaneous dual-parameter viewing, with 50,000 counts resolution and a fixed 10 Ω continuity threshold. DC voltage accuracy reaches 0.02%.


Current measurements extend to 10 A AC and DC. Frequency measurements reach 500 kHz with 0.01 Hz resolution. Resistance testing covers up to 50 MΩ with 10 mΩ resolution.


The meter includes diode testing and AC + DC voltage and current support.


Technical Specifications



  • DC Voltage: 0.02% accuracy

  • AC Voltage: Supported

  • DC Current: Up to 10 A

  • AC Current: Up to 10 A

  • AC + DC Voltage: Supported

  • AC + DC Current: Supported

  • Resistance: Up to 50 MΩ with 10 mΩ resolution

  • Frequency: Up to 500 kHz with 0.01 Hz resolution

  • Continuity Test: Fixed 10 Ω threshold

  • Diode Test: Supported

  • Display: 4.5-digit VFD with 50,000 counts resolution

  • Input Voltage: 90 VAC to 264 VAC, 50/60 Hz


Key Features



  • Dual VFD display for simultaneous dual readings

  • Math functions: dBm (2 Ω to 8000 Ω reference impedance), REL, Min/Max, COMP, Hold, Percentage

  • USB connectivity for data logging

  • Kensington lock slot for security

  • Anti-slip protective bumpers on front and rear panels

  • Indoor use design


Typical Applications



  • Electronics testing and troubleshooting

  • Educational environments

  • Communications and test setups


Compatibility & Integration The U3401A operates across standard worldwide AC power distributions (90–264 VAC, 50/60 Hz) and integrates USB connectivity for automated data logging in bench and field measurement scenarios.

Agilent / Keysight U3401A — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Agilent / Keysight U3401A. Calibration covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Agilent / Keysight U3401A faults: blown input fuse, worn input jacks, display segment failure, relay contact wear on bench DMMs. Common faults include worn input jacks (banana socket contact wear on the mA and COM terminals), blown input fuses (especially the 440 mA HRC fuse), and display segment failures. Keithley 2000/2001/2002 bench DMMs commonly develop relay contact wear affecting resistance accuracy after extended service.

Agilent / Keysight U3401A price

This Agilent / Keysight U3401A is listed at $450. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Agilent / Keysight U3401A calibration cost

NIST-traceable calibration for the Agilent / Keysight U3401A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents