Yokogawa AQ2200-332 Optical Attenuator Module
The Yokogawa AQ2200-332 is an optical attenuator module designed for use with the AQ2200 Multi Application Test System. It provides precise and reliable attenuation of optical signals, essential for testing and characterizing optical communication systems and components. This module offers a wide attenuation range and high resolution, ensuring accurate measurements in various applications.
- Model
- Yokogawa AQ2200-332
- Calibration
- Available on request
- Price
- $2,555
- Status
- In stock
- RFQ ref
- AQ2200-332
This unit
The Yokogawa AQ2200-332 is a single-slot optical attenuator module for the AQ2200 Multi Application Test System. It delivers precise optical signal attenuation across a broad wavelength range while simultaneously monitoring output power through an integrated optical power meter. The module combines variable optical attenuation with real-time power measurement in a compact footprint, making it essential for bit error testing, optical attenuator evaluation, and photoreceptor characterization in laboratory and field environments.
Technical Specifications
Optical Performance- Wavelength range: 800 to 1700 nm (SMF: 1200–1700 nm; MMF: 800–1370 nm)
- Attenuation range: Up to 60 dB (SMF), up to 45 dB (MMF)
- Attenuation accuracy: ±0.1 dB
- Attenuation resolution: 0.001 dB
- Insertion loss: 1.9 dB (typical)
- Return loss: >45 dB (typical), >20 dB (minimum)
- Polarization dependent loss: <0.1 dBp-p
- Maximum input power: +23 dBm Fiber Support
- Single Mode Fiber (SMF): 10/125 µm
- Multi-Mode Fiber (MMF): 50/125 µm, 62.5/125 µm Physical & Mechanical
- Dimensions: 31 mm (W) × 117 mm (H) × 31.5 mm (D)
- Weight: 0.9 kg
- Optical connector: FC/PC
Key Features
- Integrated optical power meter for direct output power monitoring and setup
- Single-slot module design for minimal footprint within the AQ2200 chassis
- Fine attenuation control with 0.001 dB resolution and ±0.1 dB accuracy
- Supports both single-mode and multi-mode fiber across extended wavelength bands
- Low polarization dependent loss ensures minimal signal distortion
Typical Applications
- Bit error rate (BER) testing and optical link characterization
- Variable optical attenuator (VOA) evaluation and validation
- Photoreceptor output linearity measurement
- Optical communication system component testing
Compatibility & Integration Designed for the Yokogawa AQ2200 Multi Application Test System (firmware 3.04 and later). Integrates with other AQ2200 series modules and Yokogawa optical communication instruments to build modular measurement configurations.
Specifications
| Parameter | Value |
|---|---|
| Power Range (dBm) | '+23 dBm (maximum input) | Wavelength Range: 800 to 1700 nm (SMF: 1200–1700 nm |
| MMF | 800–1370 nm) |
Yokogawa AQ2200-332 — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Yokogawa AQ2200-332. Calibration covers attenuation accuracy at 5 or more set values across the full range (0 to rated maximum dB), attenuation linearity, wavelength-dependent attenuation at 1310 nm, 1490 nm, and 1550 nm, insertion loss at minimum attenuation (0 dB position), and polarization-dependent loss (PDL) where applicable. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common Yokogawa AQ2200-332 faults: motor and gear mechanism wear (attenuation steps or loss of smooth control), optical port contamination, EEPROM calibration data corruption. Most common faults are motor or gear mechanism wear on variable attenuators causing attenuation steps or loss of smooth control, optical port contamination reducing dynamic range, and EEPROM calibration data corruption on digitally controlled models.
Yokogawa AQ2200-332 price
This Yokogawa AQ2200-332 is listed at $2,555. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Yokogawa AQ2200-332 calibration cost
NIST-traceable calibration for the Yokogawa AQ2200-332 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers attenuation accuracy at 5 or more set values across the full range (0 to rated maximum dB), attenuation linearity, wavelength-dependent attenuation at 1310 nm, 1490 nm, and 1550 nm, insertion loss at minimum attenuation (0 dB position), and polarization-dependent loss (PDL) where applicable. Turnaround is 1 to 3 business days after receipt. See full calibration details →