Ando AQ6319 600-1700nm Optical Spectrum Analyzer

Ando AQ6319 600-1700nm Optical Spectrum Analyzer,An advanced optical spectrum analyzer supporting a wide range from 600 to 1700nm. It provides precise measurement for DWDM systems, laser testing, and optical component characterization. Known for low noise, fast sweep speeds, and comprehensive analysis features for telecom and R&D applications.

Model
Ando AQ6319
Calibration
Available on request
Price
$8,970
Status
In stock
RFQ ref
AQ6319
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

Ando AQ6319 600-1700nm Optical Spectrum Analyzer,This optical spectrum analyzer supports analysis from 600 to 1700 nm, offering broad wavelength coverage suitable for testing various fiber optic systems and components. With high resolution and sensitivity, it enables precise measurement of optical power, wavelength, and spectral distribution. Fast sweep capabilities and multiple trace storage enhance usability for comparing live and stored signals. It supports absolute and relative measurements, enabling evaluation of optical sources, filters, and amplifiers. The interface includes graphical tools for peak search, marker readout, and automatic measurement functions, streamlining operation for users at all levels. Connectivity options such as GPIB allow integration into automated test setups. Its rugged design and stable performance make it ideal for both R&D and production environments. The display offers real-time visualization of complex signals with adjustable scaling and trace averaging. Internal calibration ensures long-term measurement stability, and diagnostic tools assist in maintaining performance over extended use. This instrument is especially valuable for optical engineers working with WDM, passive components, and lightwave systems needing high-quality spectral analysis with dependable accuracy and repeatability.

Frequently Asked Questions

What wavelength range and measurements does the Ando AQ6319 cover?
The AQ6319 operates across 600–1700 nm, making it ideal for DWDM system validation, laser characterization, and optical component testing in telecom and R&D environments. It delivers low-noise floor performance with fast sweep speeds, allowing you to resolve individual channels in dense wavelength-division multiplexed systems and measure spectral features with high resolution. The instrument supports both peak and power-level analysis across the full infrared and visible spectrum window.
What condition is this unit in, and what was verified before listing?
This Ando AQ6319 is offered in used condition and has been functionally tested prior to listing to ensure measurement accuracy and basic operational integrity. We verify core sweep functionality, display response, and wavelength calibration reference points before releasing any spectrum analyzer to inventory. Detailed condition notes and any cosmetic observations are available upon request.
Is calibration available, and what does it cover for this analyzer?
Yes, full traceable calibration is available separately, starting at $450, and covers wavelength accuracy and optical power reference calibration for the AQ6319 across its operating range. Calibration includes NIST-traceable certification and a formal calibration certificate valid for your records and compliance documentation. Standard turnaround time and specific scope details can be confirmed when you request a calibration quote.
What interfaces and software support does the AQ6319 offer?
The AQ6319 features GPIB (IEEE 488.2) connectivity for remote instrument control and data logging, enabling integration into automated test systems and lab networks. Compatible drivers and command sets support industry-standard measurement software platforms used in telecom and optical labs. USB and Ethernet connectivity options may vary by unit configuration; verify specific interface availability when confirming your model's exact feature set.

Ando AQ6319 — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Ando AQ6319. Calibration covers wavelength accuracy at 850, 1310, 1550, and 1625 nm, power level accuracy, resolution bandwidth (RBW) accuracy, and dynamic range verification. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Ando AQ6319 faults: wavelength motor failure, internal light source dimming, detector sensitivity loss. Common repairs include wavelength motor servicing, internal broadband source replacement, and detector recalibration after extended use.

Ando AQ6319 price

This Ando AQ6319 is listed at $8,970. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Ando AQ6319 calibration cost

NIST-traceable calibration for the Ando AQ6319 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers wavelength accuracy at 850, 1310, 1550, and 1625 nm, power level accuracy, resolution bandwidth (RBW) accuracy, and dynamic range verification. Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents