Yokogawa AQ6376E 1500-3400nm Optical Spectrum Analyzer
The Yokogawa AQ6376E is an optical spectrum analyzer that operates in the 1500-3400nm wavelength range. It is used to measure the spectral characteristics of light sources and optical components. It features high wavelength accuracy and resolution, making it suitable for demanding applications.
- Model
- Yokogawa AQ6376E
- Calibration
- Available on request
- Price
- $58,730
- Status
- In stock
- RFQ ref
- AQ6376E
This unit
The Yokogawa AQ6376E is a bench-top optical spectrum analyzer covering 1500–3400 nm, extending into the Mid-Wave Infrared region. It delivers high-accuracy wavelength measurements, exceptional sensitivity down to −65 dBm, and a 78 dB measurement dynamic range. The instrument supports both free-space and fiber-coupled inputs (single-mode and multimode up to 400 µm) and executes full-span sweeps in as little as 0.5 seconds using Double Speed Mode.
Built-in gas purging, cut filtering, and fast auto-calibration eliminate common measurement artifacts. Advanced Pulsed Light Measurement capability and a double-pass monochromator design enable precise characterization of environmental gases (COx, NOx, CxHy), laser sources, and infrared optical components in R&D and manufacturing environments.
Technical Specifications
- Wavelength range: 1500–3400 nm
- Wavelength accuracy: ±0.5 nm
- Wavelength resolution: 0.1 nm
- Close-in dynamic range: 55 dB
- Measurement dynamic range: 78 dB
- Level sensitivity: −65 dBm
- Optical input: Free-space and fiber-coupled (single-mode, multimode to 400 µm)
- Sweep time: 0.5 seconds minimum (100 nm span, Double Speed Mode)
- Double-pass monochromator for high resolution and dynamic range
Key Features
- Double Speed Mode for up to 2× faster sweep performance
- Advanced Pulsed Light Measurement (APLM) mode
- Gas purging ports to reduce water vapor absorption
- Built-in cut filter for high-order diffraction suppression
- Fast auto-calibration with internal reference source (<2 minutes)
- 55 dB close-in dynamic range for signal separation
- Large touchscreen display for intuitive operation
- Built-in parameter analysis for automatic device characterization
- Ethernet interface for high-speed data transfer
Typical Applications
- Environmental gas sensing and monitoring (COx, NOx, hydrocarbons)
- Laser spectroscopy and source characterization
- Optical device and component testing in the infrared
- Manufacturing quality assurance for infrared optical systems
Compatibility & Integration Accepts single-mode and multimode fiber inputs up to 400 µm diameter. Supports external reference sources for wavelength calibration. Ethernet connectivity enables rapid remote measurement and data logging.
Specifications
| Parameter | Value |
|---|---|
| Power Range (dBm) | '-65 dBm to measurement dynamic range 78 dB | Wavelength Range: 1500 nm to 3400 nm |
Frequently Asked Questions
- What does the Yokogawa AQ6376E measure and what is its wavelength range?
- The AQ6376E is an optical spectrum analyzer designed to measure spectral characteristics of light sources and optical components across the 1500–3400 nm wavelength range. It delivers a power measurement range of −65 dBm with a dynamic range of 78 dB, making it suitable for demanding infrared and near-infrared applications. The instrument provides high wavelength accuracy and resolution for precise spectral analysis in telecommunications, fiber-optic testing, and photonics research.
- What is the condition of this used AQ6376E, and what was verified?
- This unit is offered in used condition and has been inspected for operational integrity. We verify basic functionality and mechanical condition prior to listing; however, comprehensive calibration certification is available separately to ensure measurement accuracy to factory specifications. Interested buyers should confirm any specific performance requirements with our sales team before purchase.
- What calibration services are available for the AQ6376E?
- Calibration services for the AQ6376E are available separately, starting at $450, and typically cover wavelength accuracy and power measurement verification to Yokogawa standards. Turnaround time and specific scope of calibration can be discussed with our team upon request. We recommend calibration certification for applications requiring traceable measurement data or compliance documentation.
- What interfaces and connectivity options does the AQ6376E have?
- The Yokogawa AQ6376E supports industry-standard interfaces for remote operation and data acquisition, enabling integration into automated test systems and network environments. Compatible software drivers and communication protocols allow seamless connectivity with measurement control software. For detailed specifications on available ports (GPIB, USB, Ethernet, or LAN) and driver compatibility for your specific application, please contact Aumictech directly.
Yokogawa AQ6376E — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Yokogawa AQ6376E. Calibration covers wavelength accuracy at 850, 1310, 1550, and 1625 nm, power level accuracy, resolution bandwidth (RBW) accuracy, and dynamic range verification. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common Yokogawa AQ6376E faults: wavelength motor failure, internal light source dimming, detector sensitivity loss. Common repairs include wavelength motor servicing, internal broadband source replacement, and detector recalibration after extended use.
Yokogawa AQ6376E price
This Yokogawa AQ6376E is listed at $58,730. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Yokogawa AQ6376E calibration cost
NIST-traceable calibration for the Yokogawa AQ6376E is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers wavelength accuracy at 850, 1310, 1550, and 1625 nm, power level accuracy, resolution bandwidth (RBW) accuracy, and dynamic range verification. Turnaround is 1 to 3 business days after receipt. See full calibration details →