Anritsu MS9001B Spectrum Analyzer 600nm – 1750nm Calibrated

Anritsu Optical Spectrum Analyzers. Power Range: -70 dBm to +10 dBm (0.7–1.6 µm), Accuracy: ±2 dB absolute optical level (measured at 0.85 µ, Accuracy: ±0.1 nm.

Model
Anritsu MS9001B
Calibration
Available on request
Price
$3,400
Status
In stock
RFQ ref
MS9001B
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Anritsu MS9001B is an optical spectrum analyzer engineered for precise spectral characterization across the 600 nm to 1750 nm wavelength range. It delivers calibrated measurements of light sources and optical components, making it essential for optical communications development, component validation, and loss characterization in fiber optic systems.


Technical Specifications

Wavelength Range: 600 nm to 1750 nm Input Power Range: -70 dBm to +10 dBm (0.7–1.6 µm); -65 dBm to +10 dBm (0.6–0.7 µm and 1.6–1.75 µm); -70 dBm to +20 dBm (MS9001B1 variant) Power Accuracy: ±2 dB absolute optical level (measured at 0.85 µm, 1.31 µm, 1.55 µm) Wavelength Accuracy: ±0.1 nm Linearity: ±0.5 dB/20 dB; ±1 dB/60 dB Resolution Bandwidth: 0.01 nm to 5 nm Dynamic Range: 45–50 dB Sweep Time: 3.5 seconds (5500 nm sweep width); 0.3 seconds high-speed (0–2 ns sweep width) Operating Temperature: 10°C to 40°C Interfaces: GPIB standard; RS-232 and USB available (MS9001B1)

Key Features



  • Optimized for 1.55 µm optical communication wavelengths and broadband analysis from visible to mid-infrared

  • Selectable resolution bandwidth (0.01–5 nm) for source linewidth and filter characterization

  • Rapid sweep acquisition supports both standard and high-speed measurement modes

  • ±2 dB absolute power accuracy across critical telecom wavelengths

  • Built-in analysis functions: LD spectrum, LED spectrum, fiber loss, filter transmission

  • GPIB remote control for automated test sequences


Typical Applications



  • Laser diode and LED spectral characterization

  • Optical component loss measurement (filters, couplers, fiber segments)

  • White-light source analysis (compatible with broadband sources)

  • Optical communication system validation and troubleshooting


Compatibility & Integration The MS9001B connects via standard GPIB interface. The MS9001B1 variant adds RS-232 and USB connectivity. Physical dimensions approximately 426 mm (W) × 177 mm (H) × 487 mm (D); weight approximately 15–30 kg depending on configuration.

Specifications

ParameterValue
Power Range (dBm)'-70 dBm to +10 dBm (0.7–1.6 µm)
-70 dBm to +20 dBm (MS9001B1) | Wavelength Range600 nm to 1750 nm

Frequently Asked Questions

What does the Anritsu MS9001B measure and what is its wavelength range?
The MS9001B is an optical spectrum analyzer designed to measure optical power across a wavelength range of 600 nm to 1750 nm, covering visible through infrared regions. It provides a power measurement range of −70 dBm to +10 dBm across the 0.7–1.6 µm band, with absolute optical level accuracy of ±2 dB (measured at 0.85 µm) and wavelength accuracy of ±0.1 nm. This instrument is ideal for characterizing optical sources, monitoring WDM systems, and validating optical component performance in telecommunications and fiber-optic applications.
What is the condition of this used MS9001B, and what has been verified?
This MS9001B is offered in used condition and has been inspected and tested for operational functionality before listing. We verify that all primary measurement functions operate within specification, including power detection across the full wavelength range and display accuracy. However, we recommend obtaining a current calibration certificate to ensure measurement traceability to NIST standards if your application requires documented accuracy.
Is calibration available for the MS9001B, and what does it cover?
Yes, calibration services are available separately, starting at $450 for the MS9001B. A full calibration typically covers optical power measurement accuracy at reference wavelengths, wavelength accuracy verification, and absolute level tracing to recognized standards. We recommend contacting us directly to discuss your specific calibration requirements, frequency, and turnaround time expectations.
What are the connectivity and interface options on the MS9001B?
The MS9001B supports GPIB (IEEE 488) interface for remote control and data acquisition, enabling integration into automated test systems and laboratory environments. Standard measurement software and compatible drivers are available to support data logging, spectral analysis, and system integration. For detailed information on USB or Ethernet adapter availability and compatible software versions for your operating system, please contact our technical team.

Anritsu MS9001B — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Anritsu MS9001B. Calibration covers wavelength accuracy at 850, 1310, 1550, and 1625 nm, power level accuracy, resolution bandwidth (RBW) accuracy, and dynamic range verification. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Anritsu MS9001B faults: wavelength motor failure, internal light source dimming, detector sensitivity loss. Common repairs include wavelength motor servicing, internal broadband source replacement, and detector recalibration after extended use.

Anritsu MS9001B price

This Anritsu MS9001B is listed at $3,400. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Anritsu MS9001B calibration cost

NIST-traceable calibration for the Anritsu MS9001B is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers wavelength accuracy at 850, 1310, 1550, and 1625 nm, power level accuracy, resolution bandwidth (RBW) accuracy, and dynamic range verification. Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents