Ando Tunable Laser Sources. Resolution: 10 pm, Accuracy: ±0.2 nm, Wavelength: dependent optical measurements.
- Model
- Ando AQ8201-13B
- Calibration
- Available on request
- Price
- $779
- Status
- In stock
- RFQ ref
- AQ8201-13B
This unit
The Ando AQ8201-13B is an external cavity laser (ECL) light source module designed for optical testing and measurement in telecommunications, fiber optics, and research applications. This tunable laser source delivers stable, accurate optical output across the C-band and L-band spectrum, functioning as a plug-in module within the Ando AQ8200 Series Optical Test and Measurement System. The module occupies a single slot and integrates into compatible mainframes to support DWDM-related component evaluation and characterization.
Technical Specifications
Wavelength range: 1500 nm to 1620 nm
Wavelength setting resolution: 10 pm
Wavelength accuracy: ±0.2 nm
Wavelength repeatability: ±50 pm (typical)
Wavelength setting time: 3 seconds (typical)
Spectral linewidth (Coherence Control OFF): 5 MHz (typical)
Spectral linewidth (Coherence Control ON): 100 MHz (typical)
Optical output level: +6 dBm (typical)
Optical power stability: ±0.005 dB
Laser type: ECL (External Cavity Laser)
Laser classification: Class 3A per EN60825-1:1994+A11:1996 and 21CFR 1040.10
Fiber output: 9/125 µm single-mode fiber, FC/APC connector
Key Features
High-resolution wavelength tuning across 1500–1620 nm with 10 pm steps
Exceptional wavelength stability (±0.005 dB power stability)
Fast wavelength settling at 3 seconds typical
Switchable coherence control for linewidth optimization
Compact single-slot module form factor
Typical Applications
DWDM component testing and validation
Optical fiber characterization
Telecommunications system evaluation
Wavelength-dependent optical measurements
Compatibility & Integration The AQ8201-13B mounts in Ando AQ8201, AQ8202, and AQ8203 mainframes supporting 3 or 10 module configurations. LabVIEW driver support is available for system integration. Operating specifications are assured at 20–30 °C or 25 ±3 °C; warm-up time of one hour is required before measurement.
Specifications
| Parameter | Value |
|---|---|
| Power Range (dBm) | '+6 dBm (typical) | Wavelength Range: 1500 nm to 1620 nm |
Ando AQ8201-13B — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Ando AQ8201-13B. Calibration covers wavelength accuracy at 5 or more points across the full tuning range, mode-hop-free range, output power flatness, linewidth, and side-mode suppression ratio (SMSR). All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common Ando AQ8201-13B faults: output power drift, mode hops, fiber pigtail connector damage, wavelength inaccuracy. Common faults include output power drift after extended use, mode hops at specific wavelengths, and fiber pigtail connector damage. Full alignment and piezo calibration typically restore performance to spec.
Ando AQ8201-13B price
This Ando AQ8201-13B is listed at $779. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Ando AQ8201-13B calibration cost
NIST-traceable calibration for the Ando AQ8201-13B is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers wavelength accuracy at 5 or more points across the full tuning range, mode-hop-free range, output power flatness, linewidth, and side-mode suppression ratio (SMSR). Turnaround is 1 to 3 business days after receipt. See full calibration details →