Ameritec CRS-D

Ameritec Embedded Test Systems. Model: CRS-D.

Model
Ameritec CRS-D
Calibration
Available on request
Price
$2,200
Status
In stock
RFQ ref
CRS-D
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Ameritec CRS-D Crescendo is a digital call generator that simulates telephony subscribers placing calls into network infrastructure for comprehensive testing of telecommunications equipment. It supports up to 192 simultaneous calls across eight T1 interfaces (24 channels per T1 at 1.544 Mbps) or equivalent E1 capacity (2.048 Mbps), and scales to thousands of virtual subscribers when networked with other Ameritec Crescendo, Niagara, or Squirt units. The platform accommodates analog loop-start circuits, T1 CAS trunks, E1 CAS trunks, BRI, optional PRI (in four-trunk increments), optional SS7/C7 signaling (in four-trunk increments), and Northern Telecom EBS interfaces, enabling realistic test scenarios across diverse network topologies.


Technical Specifications



  • Simultaneous Call Capacity: 192 calls (8 T1 interfaces × 24 channels)

  • T1 Interface: Eight 1.544 Mbps PCM T1 CAS trunks (two groups of four)

  • E1 Interface: Eight 2.048 Mbps PCM E1 CAS trunks (two groups of four)

  • BRI Support: Yes

  • PRI Option: Four-trunk increments

  • SS7/C7 Signaling Option: Four-trunk increments with dedicated Common Channel Signaling processor

  • Analog Circuits: Loop start lines supported

  • Northern Telecom EBS: P-phone protocol supported

  • Software Control: Ameritec FeatureCall GUI (Windows-based), manages up to 32 Crescendo units over TCP/IP LAN


Key Features



  • User-defined Call Scripts enable independent subscriber action control

  • Voice replay capability: up to 64 two-second messages (limited on ISDN-PRI and SS7 options)

  • Multi-party call simulation for conference testing

  • Script functions include signaling, dialing, Voice over Packet, digit decoding, tone send/receive, and path verification

  • Ameritec ScriptMate provides graphical test script development via Call Flow Diagrams


Typical Applications



  • Switch and trunk testing

  • Network infrastructure validation

  • Development and regression testing

  • QA testing under high-volume call loads

  • Interactive application simulation


Compatibility & Integration The CRS-D operates as a standalone unit or integrates into larger test systems via FeatureCall LAN control, enabling distributed load generation across multiple Crescendo platforms.

Ameritec CRS-D — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Ameritec CRS-D. Calibration covers analog input channel accuracy and offset at all gain settings, analog output accuracy, digital I/O logic threshold verification, sample rate and timing accuracy, and trigger and synchronization bus functional verification. NI CompactRIO and PXI chassis also undergo backplane trigger line integrity check.. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Ameritec CRS-D faults: power supply failure (cRIO-9073/9074), C-series slot connector wear, PXI chassis fan failure, GPIB interface failure on VXI controllers, BIOS/EEPROM corruption. NI CompactRIO most common faults are power supply failure on older cRIO-9073/9074 chassis and C-series module slot connector wear from repeated hot-swap cycles. PXI chassis fan failure is the most common wear item — chassis fans are field-replaceable. VXI embedded controllers most commonly develop EEPROM corruption and GPIB interface failure.

Ameritec CRS-D price

This Ameritec CRS-D is listed at $2,200. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Ameritec CRS-D calibration cost

NIST-traceable calibration for the Ameritec CRS-D is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers analog input channel accuracy and offset at all gain settings, analog output accuracy, digital I/O logic threshold verification, sample rate and timing accuracy, and trigger and synchronization bus functional verification. NI CompactRIO and PXI chassis also undergo backplane trigger line integrity check.. Turnaround is 1 to 3 business days after receipt. See full calibration details →